RESTORATION OF TISSUE-COMPONENTS AFTER INSERTION OF ABSORBABLE FRACTURE FIXATION DEVICES OF POLYGLYCOLIDE THROUGH THE ARTICULAR SURFACE - AN EXPERIMENTAL-STUDY IN THE DISTAL RABBIT FEMUR

被引:8
作者
BOSTMAN, O
PAIVARINTA, U
机构
[1] Department of Orthopaedics and Traumatology, University Central Hospital, Helsinki
关键词
D O I
10.1002/jor.1100120313
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Absorbable implants for fracture fixation do not require a secondary removal procedure, a fact that could make them particularly suitable for intra-articular fixation, provided the degree of regeneration of the articular surface is acceptable. To determine the restoration pattern in distal rabbit femurs after the intra-articular insertion of absorbable fixation devices, polyglycolide pins and screws were implanted through the articular surface of the intercondylar portion of the bone in adult animals. The polymer was known to have a degradation time of approximately 20 weeks. At follow-up times of 3-48 weeks, the restoration of the tissue components was examined histomorphometrically and microradiographically. The intact contralateral femur served as an internal control. The first signs of degradation of the implants were seen at 6 weeks. The mean fractional osteoid formation surface of the bone trabeculae within the sample fields showed significantly increased values until 6 weeks but thereafter approached the level of the control femur. In the 36-week and 48-week specimens, the polyglycolide had been absorbed and the intra-articular entrance of the implant channel had become filled either with firm whitish tissue resembling mature articular cartilage or with soft undifferentiated mesenchymal tissue only. Good restoration of the trabecular bone architecture corresponding to the original subchondral bone was a prerequisite for the regeneration of the articular cartilage. The causes of the dichotomous pattern of restoration could not be identified, but possibly it represented a normal biologic variation. Since instability associated with fracture fixation, not an issue of this study, could affect the quality of tissue restoration, the present findings call for caution if large-diameter absorbable devices are to be inserted through articular surfaces in clinical practice.
引用
收藏
页码:403 / 411
页数:9
相关论文
共 35 条
  • [1] BARFOD G, 1992, ACTA ORTHOP SCAND, V63, P680
  • [2] DEGRADATION AND TISSUE REPLACEMENT OF AN ABSORBABLE POLYGLYCOLIDE SCREW IN THE FIXATION OF RABBIT FEMORAL OSTEOTOMIES
    BOSTMAN, O
    PAIVARINTA, U
    PARTIO, E
    VASENIUS, J
    MANNINEN, M
    ROKKANEN, P
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) : 1021 - 1031
  • [3] POLYMERIC DEBRIS FROM ABSORBABLE POLYGLYCOLIDE SCREWS AND PINS - INTRAOSSEOUS MIGRATION STUDIED IN RABBITS
    BOSTMAN, O
    PAIVARINTA, U
    MANNINEN, M
    ROKKANEN, P
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (05): : 555 - 559
  • [4] FOREIGN-BODY REACTIONS TO FRACTURE FIXATION IMPLANTS OF BIODEGRADABLE SYNTHETIC-POLYMERS
    BOSTMAN, O
    HIRVENSALO, E
    MAKINEN, J
    ROKKANEN, P
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (04): : 592 - 596
  • [5] OSTEOLYTIC CHANGES ACCOMPANYING DEGRADATION OF ABSORBABLE FRACTURE FIXATION IMPLANTS
    BOSTMAN, OM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04): : 679 - 682
  • [6] INTENSE GRANULOMATOUS INFLAMMATORY LESIONS ASSOCIATED WITH ABSORBABLE INTERNAL-FIXATION DEVICES MADE OF POLYGLYCOLIDE IN ANKLE FRACTURES
    BOSTMAN, OM
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (278) : 193 - 199
  • [7] ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES
    BOSTMAN, OM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) : 148 - 153
  • [8] Campbell C J, 1969, Clin Orthop Relat Res, V64, P45
  • [9] BIODEGRADABLE RODS VERSUS KIRSCHNER WIRE FIXATION OF WRIST FRACTURES - A RANDOMIZED TRIAL
    CASTELEYN, PP
    HANDELBERG, F
    HAENTJENS, P
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (06): : 858 - 861
  • [10] OSTEOLYSIS AFTER BIODEGRADABLE PIN FIXATION OF FRACTURES IN CHILDREN
    FRASER, RK
    COLE, WG
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (06): : 929 - 930