DISTRIBUTION OF AORTIC MECHANICAL PROSTHETIC VALVE CLOSURE SOUND MODEL PARAMETERS ON THE SURFACE OF THE CHEST

被引:20
作者
BAYKAL, A [1 ]
IDER, YZ [1 ]
KOYMEN, H [1 ]
机构
[1] BILKENT UNIV,DEPT ELECT & ELECTR ENGN,ANKARA 06530,TURKEY
关键词
D O I
10.1109/10.376129
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It has been previously proposed that heart valve closure sounds can be modeled by a sum of decaying sinusoids, based on the hypothesis that the heart cavity, heart walls, major vessels, and other structures in the chest constitute a frequency selective linear acoustic system and this system is excited by the rapidly decelerating valve occluder, In this study, distribution of the parameters of this model for the second heart sound is investigated, For this purpose, heart sounds of 10 patients who have a St, Jude-type bileaflet mechanical heart valve prosthesis in aortic position are recorded, Recordings are performed at 12 different locations on the surface of the chest, To reliably assign representative parameters to each recording site, signal averaging, model order selection, and a special filtration technique are employed, The results of the analyses are discussed in relation to the above hypothesis on the heart sound generation mechanism, It is observed that site-to-site variation of frequencies of modes does not exceed the accuracy limit of proposed analysis method, but energies of these modes vary on the surface of the chest, and as a result of statistical analysis, it appears that energy of some modes are significantly different between two recording sites.
引用
收藏
页码:358 / 370
页数:13
相关论文
共 18 条
[1]   CLINICAL VALUE OF FREQUENCY ANALYSIS OF FIRST HEART SOUND IN MYOCARDIAL INFARCTION [J].
ADOLPH, RJ ;
STEPHENS, JF ;
TANAKA, K .
CIRCULATION, 1970, 41 (06) :1003-&
[2]   NEW LOOK AT STATISTICAL-MODEL IDENTIFICATION [J].
AKAIKE, H .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1974, AC19 (06) :716-723
[3]   DETECTION OF CORONARY OCCLUSIONS USING AUTOREGRESSIVE MODELING OF DIASTOLIC HEART SOUNDS [J].
AKAY, M ;
SEMMLOW, JL ;
WELKOWITZ, W ;
BAUER, MD ;
KOSTIS, JB .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (04) :366-373
[4]   SPECTRAL-ANALYSIS OF HEART SOUNDS - RELATIONSHIPS BETWEEN SOME PHYSICAL CHARACTERISTICS AND FREQUENCY-SPECTRA OF 1ST AND 2ND HEART SOUNDS IN NORMALS AND HYPERTENSIVES [J].
ARNOTT, PJ ;
PFEIFFER, GW ;
TAVEL, ME .
JOURNAL OF BIOMEDICAL ENGINEERING, 1984, 6 (02) :121-128
[5]   SPECTRAL ENERGY OF 1ST HEART SOUND IN ACUTE MYOCARDIAL ISCHEMIA - CORRELATION WITH ELECTROCARDIOGRAPHIC, HEMODYNAMIC, AND WALL MOTION ABNORMALITIES [J].
CLARKE, WB ;
AUSTIN, SM ;
SHAH, PM ;
GRIFFEN, PM ;
DOVE, JT ;
MCCULLOUGH, J ;
SCHREINER, BF .
CIRCULATION, 1978, 57 (03) :593-598
[6]  
DURAND LG, 1987, IEEE T BIOMED ENG, V37, P1121
[7]   SPECTROANALYTIC EVALUATION OF AORTIC PROSTHETIC VALVES [J].
GORDON, RF ;
NAJMI, M ;
KINGSLEY, B ;
SEGAL, BL ;
LINHART, JW .
CHEST, 1974, 66 (01) :44-49
[8]   SOUND SPECTROGRAPHIC DIAGNOSIS OF AORTIC BALL VARIANCE [J].
HYLEN, JC ;
KLOSTER, FE ;
HERR, RH ;
STARR, A ;
GRISWOLD, HE .
CIRCULATION, 1969, 39 (06) :849-&
[9]  
JOHNSON RA, 1982, APPLIED MULTIVARIATE, P552
[10]  
KAGAWA Y, 1980, J THORAC CARDIOV SUR, V79, P671