LIVER-BIOPSY - REVIEW OF METHODOLOGY AND COMPLICATIONS

被引:92
作者
TOBKES, AI [1 ]
NORD, HJ [1 ]
机构
[1] UNIV S FLORIDA,COLL MED,DIV DIGEST DIS & NUTR,TAMPA,FL 33606
关键词
LIVER BIOPSY; COMPLICATIONS; DEATH RATE; METHODOLOGY; REVIEW;
D O I
10.1159/000171507
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Liver biopsy remains an essential tool to confirm a suspected diagnosis and guide specific therapy in patients with liver disease. The methods available to obtain liver tisse include percutaneous needle biopsy, transjugular biopsy, image-guided needle biopsy, and laparoscopic direct vision guided needle biopsy. Advantages and disadvantages of each modality are reviewed herein. The indications for liver biopsy include evaluation of elevated aminotransferases, assessment of response to therapy of chronic liver disease, monitoring for hepatoxicity of drug therapy, and liver transplant allograft evaluation. Contraindications include impaired coagulation, significant ascites, high-grade extrahepatic biliary obstruction, echinococcal cyst, and certain anatomic abnormalities. Complications include pain, hemorrhage, bile peritonitis, penetration of abdominal viscera, pneumothorax, and death. Complications are reported in 0.06-0.32% of the patients. Death as a direct result of liver biopsy is extremely rare (0.009-0.12%). In properly selected patients, liver biopsy has a high benefit/risk ratio and is often considered the final and definitive diagnostic test.
引用
收藏
页码:267 / 274
页数:8
相关论文
共 36 条
[1]  
Iversen P., Roholm K., On aspiration biopsy of the liver with remarks on its diagnostic significance, Acta Med Scand, 102, pp. 1-16, (1939)
[2]  
Menghini G., One second biopsy of the liver, Gastroenterology, 35, pp. 190-199, (1958)
[3]  
Nord H.J., Biopsy diagnoses of cirrhosis: Blind percutaneous versus guided direct vision technique. A review, Gastrointest Endosc, 28, pp. 102-104, (1982)
[4]  
Abdi W., Millan J., Mezey E., Sampling variability on percutaneous liver biopsy, Arch Intern Med, 139, pp. 667-669, (1979)
[5]  
Vargas-Tank, Martinez L.V., Jiron M., Tru-cut and Menghini needles: Different yield in the histological diagnosis of liver disease, Liver, 5, pp. 178-181, (1985)
[6]  
Colombo M., Ninno E., Dc Franchis R., De Fazic C., Festorazzi S., Rohchi G., Tommasini M.A., Ultrasound-assisted percutaneous liver biopsy: Superiority of the Tru-cut over the Menghini needle for the diagnosis of cirrhosis, Gastroenterology, 95, pp. 487-489, (1988)
[7]  
Garcia-Tsao G., Boyer J., Outpatient liver biopsy: How safe is it?, Ann Intern Med, 118, pp. 150-153, (1993)
[8]  
Radge H., Aldape H., Bagley C., Ul-trasound-guided prostate biopsy, Urology, 32, pp. 503-506, (1988)
[9]  
Mladinich C., Ackerman N., Bern' C., Buergelt C.D., Longmate S., Evaluation and comparison of automated biopsy devices, Radiology, 184, pp. 845-847, (1992)
[10]  
Liver transplant biopsies with a biopsy gun, Radiology, 179, pp. 4447-4448, (1991)