IMAGING SOFT SAMPLES WITH THE ATOMIC-FORCE MICROSCOPE - GELATIN IN WATER AND PROPANOL

被引:322
作者
RADMACHER, M
FRITZ, M
HANSMA, PK
机构
[1] Department of Physics, University of California, Santa Barbara
关键词
D O I
10.1016/S0006-3495(95)79897-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We have imaged mica coated with thin gelatin films in water, propanol, and mixtures of these two liquids by atomic force microscopy (AFM). The elastic modulus (Young's modulus) can be tuned from 20 kPa to more than 0.1 GPa depending on the ratio of propanol to water. The resolution is best in pure propanol, on the order of 20 nm, and becomes worse for the softer samples. The degradation in resolution can be understood by considering the elastic indentation of the gelatin caused by the AFM tip. This indentation becomes larger and thus the contact area becomes larger the softer the sample is. Therefore this study may be used to estimate the resolution to be expected with an AFM on other soft samples, such as cells. Nondestructive imaging was possible only by imaging at forces <1 nN. This was difficult to achieve in contact mode because of drift in the zero load deflection of the cantilever, supposedly caused by temperature drift, but straightforward in tapping mode.
引用
收藏
页码:264 / 270
页数:7
相关论文
共 29 条
[1]   COMMENTS ON THE USE OF THE FORCE MODE IN ATOMIC-FORCE MICROSCOPY FOR POLYMER-FILMS [J].
AIME, JP ;
ELKAAKOUR, Z ;
ODIN, C ;
BOUHACINA, T ;
MICHEL, D ;
CURELY, J ;
DAUTANT, A .
JOURNAL OF APPLIED PHYSICS, 1994, 76 (02) :754-762
[2]   DIGITAL SIGNAL PROCESSOR CONTROL OF SCANNED PROBE MICROSCOPES [J].
BASELT, DR ;
CLARK, SM ;
YOUNGQUIST, MG ;
SPENCE, CF ;
BALDESCHWIELER, JD .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (07) :1874-1882
[3]  
BEZANILLA M, 1994, BIOPHYS J, V67, P1
[4]   ATOMIC FORCE MICROSCOPE [J].
BINNIG, G ;
QUATE, CF ;
GERBER, C .
PHYSICAL REVIEW LETTERS, 1986, 56 (09) :930-933
[5]  
CLARK AH, 1987, ADV POLYM SCI, V83, P57
[6]   A NONDESTRUCTIVE METHOD FOR DETERMINING THE SPRING CONSTANT OF CANTILEVERS FOR SCANNING FORCE MICROSCOPY [J].
CLEVELAND, JP ;
MANNE, S ;
BOCEK, D ;
HANSMA, PK .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (02) :403-405
[7]   ARCHITECTURE OF GELATIN GELS [J].
DJABOUROV, M .
CONTEMPORARY PHYSICS, 1988, 29 (03) :273-297
[8]   GRANULA MOTION AND MEMBRANE SPREADING DURING ACTIVATION OF HUMAN PLATELETS IMAGED BY ATOMIC-FORCE MICROSCOPY [J].
FRITZ, M ;
RADMACHER, M ;
GAUB, HE .
BIOPHYSICAL JOURNAL, 1994, 66 (05) :1328-1334
[9]   BIOMOLECULAR IMAGING WITH THE ATOMIC-FORCE MICROSCOPE [J].
HANSMA, HG ;
HOH, JH .
ANNUAL REVIEW OF BIOPHYSICS AND BIOMOLECULAR STRUCTURE, 1994, 23 :115-139
[10]   TAPPING MODE ATOMIC-FORCE MICROSCOPY IN LIQUIDS [J].
HANSMA, PK ;
CLEVELAND, JP ;
RADMACHER, M ;
WALTERS, DA ;
HILLNER, PE ;
BEZANILLA, M ;
FRITZ, M ;
VIE, D ;
HANSMA, HG ;
PRATER, CB ;
MASSIE, J ;
FUKUNAGA, L ;
GURLEY, J ;
ELINGS, V .
APPLIED PHYSICS LETTERS, 1994, 64 (13) :1738-1740