CLINICAL-PERFORMANCE OF A CONE ANNULAR ARRAY ULTRASOUND BREAST SCANNER

被引:7
作者
FISHELL, EK
FOSTER, FS
CONNOR, T
KHODAI, M
HARASCIEWICZ, K
HUNT, JW
机构
[1] ONTARIO CANC INST,DIV PHYS,500 SHERBOURNE ST,TORONTO M4X 1K9,ONTARIO,CANADA
[2] WOMENS COLL HOSP,DEPT RADIOL,TORONTO M5S 1B2,ONTARIO,CANADA
关键词
Breast; Clinical evaluation; Cone/annular array; High resolution; Transducer; Ultrasound;
D O I
10.1016/0301-5629(90)90066-L
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound is a useful adjunctive imaging modality to x-ray mammography for the detection and management of breast disease. A high resolution (0.3 mm at -6 dB) transducer consisting of co-axially aligned cone and annular array transducers has been incorporated into a prototype breast imaging system. The prototype scanner had an operating frequency of 4 MHz and scanning was performed in the prone position. We hypothesized that the increased resolution of this system would lead to improved detection of smaller, nonpalpable lesions and would thus contribute to the early detection of breast cancer. Results of a four year clinical study of the prototype involving 1743 patients are reported. The overall true positive (TP) fraction for the detection of malignancy was 52.5% compared with 86.6% for x-ray mammography. Improved performance of ultrasound approaching that of mammography is demonstrated for the youngest age group (<34 years) and for women whose breasts are predominantly dysplastic. However, the detection of nonpalpable tumours is disappointing with a TP fraction of only 22%. Causes for the failure of the prototype breast scanner to detect early breast lesions are presented and general conclusions on the use of large aperture transducers for automated breast imaging are discussed. © 1990.
引用
收藏
页码:361 / 374
页数:14
相关论文
共 43 条
[1]   AN ANNULAR ARRAY SYSTEM FOR HIGH-RESOLUTION BREAST ECHOGRAPHY [J].
ARDITI, M ;
TAYLOR, WB ;
FOSTER, FS ;
HUNT, JW .
ULTRASONIC IMAGING, 1982, 4 (01) :1-31
[2]   MAMMOGRAPHY - CONTRARY VIEW/CY [J].
BAILAR, JC .
ANNALS OF INTERNAL MEDICINE, 1976, 84 (01) :77-84
[3]  
BAILAR JC, 1977, CANCER, V39, P2783, DOI 10.1002/1097-0142(197706)39:6<2783::AID-CNCR2820390666>3.0.CO
[4]  
2-D
[5]   QUANTITATIVE-EVALUATION OF REAL-TIME ULTRASOUND FEATURES OF THE BREAST [J].
BAMBER, JC ;
DEGONZALEZ, L ;
COSGROVE, DO ;
SIMMONS, P .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1988, 14 :81-87
[6]   ADVANCES IN ULTRASOUND MAMMOGRAPHY - REMOTE FOCUS ARC SCANNING [J].
BAUM, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1980, 6 (01) :11-17
[7]   ULTRASOUND MAMMOGRAPHY [J].
BAUM, G .
RADIOLOGY, 1977, 122 (01) :199-205
[8]   MAMMOGRAPHIC SIGNS AS RISK-FACTORS FOR BREAST-CANCER [J].
BOYD, NF ;
OSULLIVAN, B ;
CAMPBELL, JE ;
FISHELL, E ;
SIMOR, I ;
COOKE, G ;
GERMANSON, T .
BRITISH JOURNAL OF CANCER, 1982, 45 (02) :185-193
[9]   ULTRASOUND MAMMOGRAPHY - A COMPARISON WITH RADIOGRAPHIC MAMMOGRAPHY [J].
COLEBEUGLET, C ;
GOLDBERG, BB ;
KURTZ, AB ;
RUBIN, CS ;
PATCHEFSKY, AS ;
SHABER, GS .
RADIOLOGY, 1981, 139 (03) :693-698
[10]   CLINICAL-EXPERIENCE WITH A PROTOTYPE REAL-TIME DEDICATED BREAST SCANNER [J].
COLEBEUGLET, C ;
GOLDBERG, BB ;
KURTZ, AB ;
PATCHEFSKY, AS ;
SHABER, GS ;
RUBIN, CS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (05) :905-911