摘要
The analysis of the 17, 2, 3, 7, 8-substituted chlorodioxins and furans (PCDDs and PCDFs), 10 polychlorinated biphenyls (PCBs) and 15 polycyclic aromatic hydrocarbons (PAHs), in ambient air and atmospheric deposition is described. The dioxin and PCB analytes are determined on the same sample. The samples which were collected using high volume samplers and deposit guages, were taken in urban and semi-urban areas. Preliminary results indicate ppq to low ppt levels for the dioxins , ppt to sub ppb levels for the PCBs and ppb levels for the PAHs.