LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING

被引:151
作者
BELLIN, MF
ZAIM, S
AUBERTON, E
SARFATI, G
DURON, JJ
KHAYAT, D
GRELLET, J
机构
[1] HOP LA PITIE SALPETRIERE,RADIOL CENT PITIE,DEPT SURG,F-75651 PARIS,FRANCE
[2] HOP LA PITIE SALPETRIERE,RADIOL CENT PITIE,DEPT ONCOL,F-75651 PARIS,FRANCE
关键词
LIVER NEOPLASMS; LIVER; MR; MAGNETIC RESONANCE (MR); CONTRAST ENHANCEMENT; RECEIVER OPERATING CHARACTERISTIC CURVE (ROC);
D O I
10.1148/radiology.193.3.7972804
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the clinical and biologic safety of superparamagnetic iron oxide (SPIO) as a contrast agent in magnetic resonance (MR) imaging and to assess its efficacy in the detection of liver metastases. MATERIALS AND METHODS: Twenty adults with liver metastases underwent MR imaging at 1.5 T before and 1 hour after infusion of SPIO. Four spin-echo (SE) sequences and One gradient-echo (GRE) sequence were used. RESULTS: There were no adverse reactions. Alterations in serum protein, serum iron, transferrin, and ferritin levels and transferrin saturation coefficient were statistically significant. The mean tumor-to-liver contrast-to-noise ratio (C/N) increased markedly with all sequences. The best postcontrast tumor-to-liver contrast was obtained with the GRE sequence (repetition time msec/echo time msec = 300/15). The mean number of apparent lesions detected after administration of SPIO increased by 12 with the proton-density-weighted SE sequences (800/30 and 2,500/30), four with the T2-weighted SE sequence (2,500/90), and seven with the GRE Sequence (300/15). CONCLUSION: SPIO is safe, increases tumor-to-liver C/Ns with some sequences, and improves the detection of liver metastases.
引用
收藏
页码:657 / 663
页数:7
相关论文
共 24 条
  • [1] ADSON MA, 1984, ARCH SURG-CHICAGO, V119, P647
  • [2] HEPATIC CIRRHOSIS AND HEPATITIS - MR IMAGING ENHANCED WITH SUPERPARAMAGNETIC IRON-OXIDE
    ELIZONDO, G
    WEISSLEDER, R
    STARK, DD
    GUERRA, J
    GARZA, J
    FRETZ, CJ
    TODD, LE
    FERRUCCI, JT
    [J]. RADIOLOGY, 1990, 174 (03) : 797 - 801
  • [3] IRON-OXIDE ENHANCED MR-IMAGING OF THE LIVER AND SPLEEN - REVIEW OF THE 1ST-5 YEARS
    FERRUCCI, JT
    STARK, DD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (05) : 943 - 950
  • [4] FOSTER JH, 1982, CANCER PRINCIPLES PR, P1553
  • [5] SUPERPARAMAGNETIC IRON OXIDE-ENHANCED MR IMAGING - PULSE SEQUENCE OPTIMIZATION FOR DETECTION OF LIVER-CANCER
    FRETZ, CJ
    ELIZONDO, G
    WEISSLEDER, R
    HAHN, PF
    STARK, DD
    FERRUCCI, JT
    [J]. RADIOLOGY, 1989, 172 (02) : 393 - 397
  • [6] DETECTION OF HEPATIC METASTASES - COMPARISON OF CONTRAST-ENHANCED CT, UNENHANCED MR IMAGING, AND IRON-OXIDE ENHANCED MR IMAGING
    FRETZ, CJ
    STARK, DD
    METZ, CE
    ELIZONDO, G
    WEISSLEDER, R
    SHEN, JH
    WITTENBERG, J
    SIMEONE, J
    FERRUCCI, JT
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (04) : 763 - 770
  • [7] GILBERT HA, 1976, FUNDAMENTAL ASPECTS, P385
  • [8] CLINICAL-APPLICATION OF SUPERPARAMAGNETIC IRON-OXIDE TO MR IMAGING OF TISSUE PERFUSION IN VASCULAR LIVER-TUMORS
    HAHN, PF
    STARK, DD
    WEISSLEDER, R
    ELIZONDO, G
    SAINI, S
    FERRUCCI, JT
    [J]. RADIOLOGY, 1990, 174 (02) : 361 - 366
  • [9] DETECTION OF FOCAL HEPATIC MASSES - PROSPECTIVE EVALUATION WITH CT, DELAYED CT, CT DURING ARTERIAL PORTOGRAPHY, AND MR IMAGING
    HEIKEN, JP
    WEYMAN, PJ
    LEE, JKT
    BALFE, DM
    PICUS, D
    BRUNT, EM
    FLYE, MW
    [J]. RADIOLOGY, 1989, 171 (01) : 47 - 51
  • [10] HENDRICK R E, 1984, Magnetic Resonance Imaging, V2, P193, DOI 10.1016/0730-725X(84)90005-5