EVALUATION OF CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE DURING EXERCISE IN NORMAL SUBJECTS

被引:36
作者
MOORE, R
SANSORES, R
GUIMOND, V
ABBOUD, R
机构
[1] UNIV BRITISH COLUMBIA,VANCOUVER GEN HOSP,DEPT ANESTHESIOL,VANCOUVER V5Z 1M9,BC,CANADA
[2] INST NACL ENFERMEDADES RESP,MEXICO CITY,MEXICO
[3] VANCOUVER GEN HOSP,LUNG FUNCT LAB,VANCOUVER V5Z 1M9,BC,CANADA
[4] UNIV BRITISH COLUMBIA,DIV RESP,VANCOUVER V6T 1W5,BC,CANADA
关键词
D O I
10.1378/chest.102.2.448
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We compared cardiac output determined simultaneously by two methods, the CO2 rebreathing technique and the thoracic electrical bioimpedance method (Bomed NCCOM-3 equipment). The studies were performed in duplicate in 11 healthy male subjects at rest and during three levels of steady-state exercise on a cycle ergometer at 60, 120, and 180 W. Cardiac output at 60 and 120 W was slightly lower (p<0.01) by the thoracic impedance method (12.2+/-SE 2.2 and 15.7+/-SE 3.5 L/min, respectively) than by the CO2 rebreathing method (14.0+/-SE 2.1 and 17.9+/-SE 3.0 L/min, respectively), suggesting a systematic bias between the two methods of measurement. However, if allowance is made for that bias, there would be acceptable agreement between the two methods at 60 and 120 W Although the results were not significantly different between the two methods at rest and at 180 W, there was no acceptable agreement between the two methods probably because the CO2 rebreathing method at rest was more liable to show error due to the small arteriovenous CO2 difference, while the impedance method was less reliable at 180 W Cardiac output by both methods correlated with O2 consumption, with the correlation being higher for cardiac output by the rebreathing method (r=0.94) than for thoracic impedance (r=0.88). The results suggest that the thoracic electrical bioimpedance method can be used for determination of cardiac output during mild or moderate levels of exercise in normal subjects.
引用
收藏
页码:448 / 455
页数:8
相关论文
共 34 条
[1]   COMPARISON OF MEASUREMENTS OF CARDIAC-OUTPUT BY BIOIMPEDANCE AND THERMODILUTION IN SEVERELY ILL SURGICAL PATIENTS [J].
APPEL, PL ;
KRAM, HB ;
MACKABEE, J ;
FLEMING, AW ;
SHOEMAKER, WC .
CRITICAL CARE MEDICINE, 1986, 14 (11) :933-935
[2]  
APPEL PL, 1987, CRIT CARE MED, V15, P394
[3]   CONTINUOUS NONINVASIVE REAL-TIME MONITORING OF STROKE VOLUME AND CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :898-901
[4]   A NEW STROKE VOLUME EQUATION FOR THORACIC ELECTRICAL BIOIMPEDANCE - THEORY AND RATIONALE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :904-909
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   CARDIAC OUTPUT IN MIDDLE-AGED PATIENTS DETERMINED WITH CO2 REBREATHING METHOD [J].
CLAUSEN, JP ;
LARSEN, OA ;
TRAPJENS.J .
JOURNAL OF APPLIED PHYSIOLOGY, 1970, 28 (03) :337-+
[7]  
CLODE M, 1969, CLIN SCI, V37, P263
[8]   DETERMINATION OF MIXED VENOUS CO2 TENSIONS BY REBREATHING [J].
COLLIER, CR .
JOURNAL OF APPLIED PHYSIOLOGY, 1956, 9 (01) :25-29
[9]   DETERMINATION OF PVBARCO2 FROM THE EXPONENTIAL CO2 RISE DURING REBREATHING [J].
DEFARES, JG .
JOURNAL OF APPLIED PHYSIOLOGY, 1958, 13 (02) :159-164
[10]   MEASUREMENT OF CARDIAC-OUTPUT BY ELECTRICAL IMPEDANCE AT REST AND DURING EXERCISE [J].
DENNISTON, JC ;
MAHER, JT ;
REEVES, JT ;
CRUZ, JC ;
CYMERMAN, A ;
GROVER, RF .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (01) :91-95