THE DEPENDENCE OF SORBENT ANALYTE TYPE ON OBSERVED DIFFERENCES IN SUPERCRITICAL FLUID EXTRACTION EFFICIENCIES EMPLOYING EXTRACTION VESSELS OF DIFFERENT DIMENSIONS

被引:7
作者
FURTON, KG
LIN, Q
机构
[1] Department of Chemistry, Florida International University, Miami, 33199, FL, University Park
关键词
SUPERCRITICAL FLUID EXTRACTION; EXTRACTION CELL DIMENSIONS; EXTRACTION FROM SORBENTS; POLYCHLORINATED BIPHENYLS;
D O I
10.1007/BF02276136
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The effect of extraction cell dimensions (i.d.:length) on supercritical fluid extraction (SFE) efficiencies of polychlorinated biphenyls (PCBs) is shown to be dependent on the type of sorbent used. For octadecylsilane (C18) sorbents, there is a significant increase in observed SFE recoveries of PCBs when the cell dimensions are made more broad (increased i.d.:length); whereas, no effect of cell geometry is observed when the common adsorbent, Florisil, is utilized. Additionally, recoveries decreased in proportion to the chlorine number, for the PCBs studied, for octadecylsilane sorbents, while no such effect was observed for Florisil. These results illustrate the magnitude of the matrix effect in SFE, which generally dominated observed recoveries, even in the simplest analyte/sorbent systems such as the one studied here.
引用
收藏
页码:185 / 187
页数:3
相关论文
共 8 条
[1]   ADSORPTION LIQUID-CHROMATOGRAPHY OF DDT AND POLYCHLORINATED BIPHENYLS [J].
AITZETMULLER, K .
JOURNAL OF CHROMATOGRAPHY, 1975, 107 (02) :411-415
[2]   HIGH-SPEED LIQUID-CHROMATOGRAPHY OF POLYCHLORINATED BIPHENYLS AND RELATED COMPOUNDS [J].
BRINKMAN, UAT ;
SEETZ, JWFL ;
REYMER, HGM .
JOURNAL OF CHROMATOGRAPHY, 1976, 116 (02) :353-363
[3]   THE QUANTITATIVE EFFECT OF MICROEXTRACTOR CELL GEOMETRY ON THE ANALYTICAL SUPERCRITICAL FLUID EXTRACTION EFFICIENCIES OF ENVIRONMENTALLY IMPORTANT COMPOUNDS [J].
FURTON, KG ;
REIN, J .
CHROMATOGRAPHIA, 1991, 31 (5-6) :297-299
[4]  
FURTON KG, 1992, ACS S SERIES, V488
[5]   ANALYTICAL-SCALE SUPERCRITICAL FLUID EXTRACTION [J].
HAWTHORNE, SB .
ANALYTICAL CHEMISTRY, 1990, 62 (11) :A633-&
[6]  
JOHNSTON KP, 1989, ACS S SERIES, V406
[7]   EFFECTS OF COLLECTION SOLVENT PARAMETERS AND EXTRACTION CELL GEOMETRY ON SUPERCRITICAL FLUID EXTRACTION EFFICIENCIES [J].
LANGENFELD, JJ ;
BURFORD, MD ;
HAWTHORNE, SB ;
MILLER, DJ .
JOURNAL OF CHROMATOGRAPHY, 1992, 594 (1-2) :297-307
[8]   FACTORS GOVERNING THE ANALYTICAL SUPERCRITICAL FLUID EXTRACTION AND SUPERCRITICAL FLUID CHROMATOGRAPHIC RETENTION OF POLYCYCLIC AROMATIC-HYDROCARBONS [J].
REIN, J ;
CORK, CM ;
FURTON, KG .
JOURNAL OF CHROMATOGRAPHY, 1991, 545 (01) :149-160