EVALUATION OF CHANGES IN SKELETAL-MUSCLE BLOOD-FLOW IN THE DOG WITH CONTRAST ULTRASONOGRAPHY

被引:4
作者
ARONSON, S [1 ]
WALKER, R [1 ]
WIENCEK, JG [1 ]
ZAROFF, JG [1 ]
FEINSTEIN, SB [1 ]
ZACHARY, L [1 ]
机构
[1] UNIV CHICAGO,DEPT SURG,CHICAGO,IL 60637
关键词
D O I
10.1097/00006534-199501000-00018
中图分类号
R61 [外科手术学];
学科分类号
摘要
Intraoperative methods to assess skeletal muscle blood now or muscle-flap perfusion during vascular reconstructive surgery are limited. At present, techniques enable only anatomic identification of the degree of patency of large vessels. We report here the first use of ultrasonography to assess dynamic changes in skeletal muscle perfusion. Baseline blood flow in the adductor muscle group of the hindlimbs of seven dogs was measured with an electromagnetic flow probe and with contrast ultrasound using the contrast agent Albunex. Blood now was manip ulated in each dog pharmacologically with random administration of intraarterial injections of Neo-Synephrine and papaverine. After each change in blood flow detected by electromagnetic now probe, no iv also was assessed qualitatively by four independent observers who graded video-recorded contrast enhancement in the muscle group on a 0 to 4 scale. Videodensitometry also was used to generate time versus intensity curves in the adductor muscle region of interest. Peak pixel intensity was determined during each flow condition. A total of 21 flow measurements were made with each assessment scheme (electromagnetic flow probe, video enhancement, videodensitometry) for each condition (7 control, 7 papaverine, 7 Neo-Synephrine). Changes in blood now assessed by video enhancement scores and changes in peak pixel intensity correlated with changes measured by electromagnetic flow probe (r = 0.84 and 0.66, respectively). We conclude that contrast ultrasound may be used to detect changes in skeletal muscle perfusion intraoperatively. Measures of muscle perfused by visual inspection of contrast enhancement and videodensitometric data were in agreement with direct measurements of changes in skeletal muscle blood now.
引用
收藏
页码:114 / 118
页数:5
相关论文
共 19 条
[1]   MYOCARDIAL DISTRIBUTION OF CARDIOPLEGIC SOLUTION AFTER RETROGRADE DELIVERY IN PATIENTS UNDERGOING CARDIAC SURGICAL-PROCEDURES [J].
ARONSON, S ;
LEE, BK ;
ZAROFF, JG ;
WIENCEK, JG ;
WALKER, R ;
FEINSTEIN, S ;
KARP, RB .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1993, 105 (02) :214-221
[2]   ASSESSMENT OF MYOCARDIAL PERFUSION DURING CABG SURGERY WITH 2-DIMENSIONAL TRANSESOPHAGEAL CONTRAST ECHOCARDIOGRAPHY [J].
ARONSON, S ;
LEE, BK ;
WIENCEK, JG ;
FEINSTEIN, SB ;
ROIZEN, MF ;
KARP, RB ;
ELLIS, JE .
ANESTHESIOLOGY, 1991, 75 (03) :433-440
[3]  
ARONSON S, 1993, ANESTH ANALG, V76, P964
[4]   CHARACTERISTICS OF ALBUNEX - AIR-FILLED ALBUMIN MICROSPHERES FOR ECHOCARDIOGRAPHY CONTRAST ENHANCEMENT [J].
BARNHART, J ;
LEVENE, H ;
VILLAPANDO, E ;
MANIQUIS, J ;
FERNANDEZ, J ;
RICE, S ;
JABLONSKI, E ;
GJOEN, T ;
TOLLESHAUG, H .
INVESTIGATIVE RADIOLOGY, 1990, 25 :S162-S164
[5]   ESTABLISHMENT OF NORMAL RANGES OF LASER DOPPLER BLOOD-FLOW IN AUTOLOGOUS TISSUE-TRANSPLANTS [J].
CLINTON, MS ;
SEPKA, RS ;
BRISTOL, D ;
PEDERSON, WC ;
BARWICK, WJ ;
SERAFIN, D ;
KLITZMAN, B .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1991, 87 (02) :299-309
[6]  
EDWARDS N, 1990, CIRCULATION S3, V82, P96
[7]  
FEINSTEIN SB, 1984, J AM COLL CARDIOL, V4, P595, DOI 10.1016/S0735-1097(84)80107-2
[8]   MINIATURE IMPLANTABLE LASER DOPPLER PROBE MONITORING OF FREE TISSUE TRANSFER [J].
FERNANDO, B ;
YOUNG, VL ;
LOGAN, SE .
ANNALS OF PLASTIC SURGERY, 1988, 20 (05) :434-442
[9]   MONITORING IN MICROVASCULAR SURGERY [J].
FURNAS, H ;
ROSEN, JM .
ANNALS OF PLASTIC SURGERY, 1991, 26 (03) :265-272
[10]   THE POTENTIAL ROLE OF MAGNETIC-RESONANCE-IMAGING IN ISCHEMIC VASCULAR-DISEASE [J].
HIGGINS, CB .