MAC REDUCTION OF ISOFLURANE BY SUFENTANIL

被引:60
作者
BRUNNER, MD
BRAITHWAITE, P
JHAVERI, R
MCEWAN, AI
GOODMAN, DK
SMITH, LR
GLASS, PSA
机构
[1] DUKE UNIV,MED CTR,DEPT ANESTHESIA,DURHAM,NC 27710
[2] ROYAL HALLAMSHIRE HOSP,DEPT ANAESTHESIA,SHEFFIELD S10 2JF,S YORKSHIRE,ENGLAND
[3] ST GEORGE HOSP,DEPT ANAESTHESIA,LONDON SW17 0QT,ENGLAND
关键词
ANESTHETICS; VOLATILE; ISOFLURANE; MINIMUM ALVEOLAR CONCENTRATION; ANALGESICS; OPIOID; SUFENTANIL; POTENCY;
D O I
10.1093/bja/72.1.42
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We have shown previously that a plasma fentanyl concentration of 1.67 ng ml(-1) reduced the MAC of isoflurane by 50%. By comparing equal degrees of MAC reduction by sufentanil, we may determine the potency ratio of these opioids. Seventy-six patients were allocated randomly to receive predetermined infusions of sufentanil, and end-tidal concentrations of isoflurane in oxygen. Blood samples were obtained 10 min after the start of the infusion, and just before and after skin incision. Any purposeful movement by the patient was recorded. The MAC reduction of isoflurane produced by sufentanil was obtained using a logistic regression model. A sufentanil plasma concentration of 0.145 ng ml(-1) (95% confidence limits 0.04, 0.26 ng ml(-1)) resulted in a 50% reduction in the MAC of isoflurane. At a plasma concentration greater than 0.5 ng ml(-1), sufentanil exhibited a ceiling effect.
引用
收藏
页码:42 / 46
页数:5
相关论文
共 37 条
  • [1] COMPUTER-ASSISTED CONTINUOUS INFUSIONS OF FENTANYL DURING CARDIAC ANESTHESIA - COMPARISON WITH A MANUAL METHOD
    ALVIS, JM
    REVES, JG
    GOVIER, AV
    MENKHAUS, PG
    HENLING, CE
    SPAIN, JA
    BRADLEY, E
    [J]. ANESTHESIOLOGY, 1985, 63 (01) : 41 - 49
  • [2] AN EVALUATION OF THE ACCURACY OF PHARMACOKINETIC DATA FOR THE COMPUTER-ASSISTED INFUSION OF ALFENTANIL
    AUSEMS, ME
    STANSKI, DR
    HUG, CC
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1985, 57 (12) : 1217 - 1225
  • [3] THE PHARMACOKINETICS OF SUFENTANIL IN SURGICAL PATIENTS
    BOVILL, JG
    SEBEL, PS
    BLACKBURN, CL
    OEILIM, V
    HEYKANTS, JJ
    [J]. ANESTHESIOLOGY, 1984, 61 (05) : 502 - 506
  • [4] INDUCTION OF ANESTHESIA WITH SMALL DOSES OF SUFENTANIL OR FENTANYL - DOSE VERSUS EEG RESPONSE, SPEED OF ONSET, AND THIOPENTAL REQUIREMENT
    BOWDLE, TA
    WARD, RJ
    [J]. ANESTHESIOLOGY, 1989, 70 (01) : 26 - 30
  • [5] PATIENT-CONTROLLED ANALGESIC THERAPY .4. PHARMACOKINETICS AND ANALGESIC PLASMA-CONCENTRATIONS OF MORPHINE
    DAHLSTROM, B
    TAMSEN, A
    PAALZOW, L
    HARTVIG, P
    [J]. CLINICAL PHARMACOKINETICS, 1982, 7 (03) : 266 - 279
  • [6] COMPARISON OF SUFENTANIL-O-2 AND FENTANYL-O-2 FOR CORONARY-ARTERY SURGERY
    DELANGE, S
    BOSCOE, MJ
    STANLEY, TH
    PACE, N
    [J]. ANESTHESIOLOGY, 1982, 56 (02) : 112 - 118
  • [7] EGER EO, 1906, AMESTHESIOLOGY, V3, P86
  • [8] FLACKE JW, 1985, ANESTH ANALG, V64, P897
  • [9] Glass PJ, 1990, ANESTHESIA, P367
  • [10] PHARMACOKINETIC MODEL-DRIVEN INFUSION OF FENTANYL - ASSESSMENT OF ACCURACY
    GLASS, PSA
    JACOBS, JR
    SMITH, LR
    GINSBERG, B
    QUILL, TJ
    BAI, SA
    REVES, JG
    [J]. ANESTHESIOLOGY, 1990, 73 (06) : 1082 - 1090