INTERFERENCE STUDIES ON A PVC-MATRIX MEMBRANE CALCIUM ION-SELECTIVE ELECTRODE BASED ON CALCIUM BIS-DI[4-(1,1,3,3-TETRAMETHYLBUTYL)PHENYL] PHOSPHATE AS SENSOR AND TRI-NORMAL-PENTYL PHOSPHATE AS SOLVENT MEDIATOR

被引:12
作者
MOODY, GJ
NASSORY, NS
THOMAS, JDR
机构
[1] Chemistry Department, UWIST, Cardiff, Wales
关键词
D O I
10.1016/0039-9140(79)80268-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Interference potentials, EM, defined as the difference between the observed potential and the potential calculated assuming that there is no interference, have been determined, and their fit to the equation EM = -(RT/F) 1n [1 + KM aB/(aCa) 1 2z discussed for a PVC-matrix membrane calcium ion-selective electrode based on calcium bis-di[4-(1,1,3,3-tetramethylbutyl)phenyl]phosphate as sensor with tri-n-pentyl phosphate as solvent mediator in mixed solutions of CaCl2BClx, where B = Li, Na, K, Mg, Zn or Cu, at total ionic strengths of 0.2, 0.4 and 0.6. Generally, KM for the alkali metal ions is considerably less for this electrode than for a comparison electrode based on Orion 92-20-02 liquid ion-exchanger in PVC. Occasionally, the data do not fit the equation. Thus, particularly for the bivalent ions, although the plots of exp[-EMF/RT] vs. aB/(aCa) 1 2z are usually linear, they frequently do not intercept the ordinate at 1.00 and/or may give negative slopes and hence negative KM values. © 1979.
引用
收藏
页码:873 / 879
页数:7
相关论文
共 28 条
[1]  
BAES CF, 1962, J INORG NUCL CHEM, V30, P1640
[2]   BIIONIC POTENTIALS OF A LIQUID-MEMBRANE ELECTRODE SELECTIVE TOWARD CALCIUM [J].
BAGG, J ;
NICHOLSO.O ;
VINEN, R .
JOURNAL OF PHYSICAL CHEMISTRY, 1971, 75 (14) :2138-&
[3]   SELECTIVITY PARAMETER AND PARTITION COEFFICIENT FOR A CALCIUM-SELECTIVE ELECTRODE [J].
BAGG, J ;
CHAUNG, WP .
AUSTRALIAN JOURNAL OF CHEMISTRY, 1971, 24 (09) :1963-&
[4]  
BAGG J, 1977, COMMUNICATION 0913
[5]   CALCIUM-SENSITIVE MICROELECTRODE SUITABLE FOR INTRACELLULAR MEASUREMENT OF CALCIUM(II) ACTIVITY [J].
BROWN, HM ;
PEMBERTON, JP ;
OWEN, JD .
ANALYTICA CHIMICA ACTA, 1976, 85 (02) :261-276
[6]   PREPARATION OF MONO-[4-(N-OCTYL)PHENYL] AND DI-[4-(N-OCTYL)PHENYL] AND [4-(1,1,3,3-TETRAMETHYLBUTYL)PHENYL]PHOSPHORIC ACIDS FOR USE IN PVC CALCIUM ION-SELECTIVE ELECTRODES [J].
CRAGGS, A ;
DELDUCA, PG ;
KEIL, L ;
KEY, BJ ;
MOODY, GJ ;
THOMAS, JDR .
JOURNAL OF INORGANIC & NUCLEAR CHEMISTRY, 1978, 40 (08) :1483-1487
[7]   PVC MATRIX MEMBRANE ION-SELECTIVE ELECTRODES - CONSTRUCTION AND LABORATORY EXPERIMENTS [J].
CRAGGS, A ;
MOODY, GJ ;
THOMAS, JDR .
JOURNAL OF CHEMICAL EDUCATION, 1974, 51 (08) :541-544
[8]   EVALUATION OF CALCIUM ION-SELECTIVE ELECTRODES BASED ON DI(N-ALKYLPHENYL)PHOSPHATE SENSORS AND THEIR CALIBRATION WITH ION BUFFERS [J].
CRAGGS, A ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1979, 104 (1238) :412-418
[9]   EVALUATION OF SOLVENT MEDIATORS FOR ION-SELECTIVE ELECTRODE MEMBRANES BASED ON CALCIUM BIS(DIALKYLPHOSPHATE) SENSORS TRAPPED IN POLYVINYL-CHLORIDE) MATRICES [J].
CRAGGS, A ;
KEIL, L ;
MOODY, GJ ;
THOMAS, JDR .
TALANTA, 1975, 22 (10-1) :907-910
[10]  
Eisenman G., 1969, ION SELECTIVE ELECTR