ALKALINE PHOSPHATASE-MODIFIED CARBON-FIBER DISK MICROELECTRODE FOR THE DETERMINATION OF 4-AMINOPHENYL PHOSPHATE

被引:12
作者
PARIENTE, F [1 ]
HERNANDEZ, L [1 ]
ABRUNA, HD [1 ]
LORENZO, E [1 ]
机构
[1] UNIV AUTONOMA MADRID,FAC CIENCIAS,DEPT QUIM ANALIT & ANAL INSTRUMENTAL,E-28049 MADRID,SPAIN
关键词
AMPEROMETRY; BIOSENSORS; ENZYMATIC METHODS; ALKALINE PHOSPHATASE-MODIFIED ELECTRODE; AMINOPHENYL PHOSPHATE; CARBON FIBER DISK MICROELECTRODE; ENZYME ELECTRODES;
D O I
10.1016/0003-2670(93)80157-G
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction and response of an alkaline phosphatase-modified carbon fibre disc microelectrode and its use as an amperometric sensor for the determination of 4-aminophenyl phosphate are described. The enzyme was immobilized on the electrode surface using glutaraldehyde and bovine serum albumin as cross-linking agents. The product of the enzymatic reaction, 4-aminophenol, was determined by oxidation at +0.3 V vs. a sodium chloride saturated calomel electrode, yielding a steady-state current directly related to the bulk concentration of the substrate. The response time of this microbiosensor was typically less than 3 s and 4-aminophenyl phosphate could be determined in the range 5.0 x 10(-7) -5.0 x 10(-3) M.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 18 条
[1]   INTRACELLULAR ANALYSIS WITH AN IMMOBILIZED-ENZYME GLUCOSE ELECTRODE HAVING A 2-MU-M DIAMETER AND SUBSECOND RESPONSE-TIMES [J].
ABE, T ;
LAU, YY ;
EWING, AG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (19) :7421-7423
[2]  
Bard A., 1980, ELECTROCHEMICAL METH
[3]   IMMOBILIZATION OF GLUCOSE-OXIDASE ON CARBON ELECTRODES [J].
BIANCO, P ;
HALADJIAN, J ;
BOURDILLON, C .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 293 (1-2) :151-163
[4]   SYNTHESIS OF MONO-NUCLEOTIDE AND DINUCLEOTIDE PHOTOAFFINITY PROBES OF RIBONUCLEIC-ACID POLYMERASE [J].
DERIEMER, LH ;
MEARES, CF .
BIOCHEMISTRY, 1981, 20 (06) :1606-1612
[5]  
FLEISCHMAN M, 1987, ULTRAMICROELECTRODES
[6]   AMPEROMETRIC SENSOR FOR HYPOXANTHINE AND XANTHINE BASED ON THE DETECTION OF URIC-ACID [J].
GONZALEZ, E ;
PARIENTE, F ;
LORENZO, E ;
HERNANDEZ, L .
ANALYTICA CHIMICA ACTA, 1991, 242 (02) :267-273
[7]   CROSS-LINKED REDOX GELS CONTAINING GLUCOSE-OXIDASE FOR AMPEROMETRIC BIOSENSOR APPLICATIONS [J].
GREGG, BA ;
HELLER, A .
ANALYTICAL CHEMISTRY, 1990, 62 (03) :258-263
[8]  
IANELLO RM, 1981, ANAL CHEM, V53, P2090
[9]   HIGH-PERFORMANCE MICRO-ENZYME SENSOR USING PLATINIZED MICROELECTRODE [J].
IKARIYAMA, Y ;
YAMAUCHI, S ;
AIZAWA, M ;
YUKIASHI, T ;
USHIODA, H .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1988, 61 (10) :3525-3530
[10]   CHRONOPOTENTIOMETRIC STUDIES ON THE OXIDATION OF FERROCENE, RUTHENOCENE, OSMOCENE AND SOME OF THEIR DERIVATIVES [J].
KUWANA, T ;
BUBLITZ, DE ;
HOH, G .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1960, 82 (22) :5811-5817