THE RELIABILITY OF A SOLID-PHASE EXTRACTION SYSTEM FOR THE ANALYSIS OF BENZOYLECGONINE IN URINE

被引:7
作者
JENNISON, TA [1 ]
JONES, CW [1 ]
WOZNIAK, E [1 ]
URRY, FM [1 ]
机构
[1] UNIV UTAH,DEPT PATHOL,SALT LAKE CITY,UT 84108
关键词
D O I
10.1093/chromsci/32.4.126
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Gas chromatographic-mass spectrometric (GC-MS) analysis for benzoylecgonine (BE), a metabolite of cocaine, requires an initial extraction from urine. Although liquid-liquid extraction methods are frequently used, solid-phase extraction (SPE) may be preferable for obtaining reliable results and clean chromatograms. We describe a 12-month study that evaluates the accuracy, precision, variability between analysts, variability between column lots, and cleanliness of BE extracts using SPE columns followed by GC-MS analysis. The overall mean for a control urine sample prepared at 150 ng/mL is 151 ng/mL (N=293) with a standard deviation of 8.59 and a coefficient of variation (CV) of 5.7%. Within-run precision (measured as CV) at 75, 150, and 2000 ng/mL is 4.0, 1.8, and 0.8%, respectively. Mean results from 10 different analysts vary a maximum of 4.6% from the overall mean of 151 ng/mL, and the CV for 9 out of 10 analysts is 7.0% or less. The CV for the remaining analyst is 10.4%. Quantitative results from nine different lots of SPE columns fluctuate 3.3% from the overall mean of 151 ng/mL, and the CV varies from 3.5 to 6.2%. GC-MS chromatograms following SPE are significantly cleaner (i.e., reduced baseline signal and no interfering peaks) than those from two types of liquid-liquid extractions. © 1994, Oxford University Press. All rights reserved.
引用
收藏
页码:126 / 131
页数:6
相关论文
共 16 条
[1]   URINARY-EXCRETION OF COCAINE, BENZOYLECGONINE, AND ECGONINE METHYL-ESTER IN HUMANS [J].
AMBRE, J ;
RUO, TI ;
NELSON, J ;
BELKNAP, S .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1988, 12 (06) :301-306
[2]   GAS CHROMATOGRAPHY-CHEMICAL IONIZATION MASS-SPECTROMETRY OF COCAINE AND ITS METABOLITES IN BIOLOGICAL-FLUIDS [J].
CHINN, DM ;
CROUCH, DJ ;
PEAT, MA ;
FINKLE, BS ;
JENNISON, TA .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1980, 4 (01) :37-42
[3]  
HAYS WL, 1981, STATISTICS, P481
[4]   MEASUREMENT OF BENZOYLECGONINE AND COCAINE IN URINE, SEPARATION OF VARIOUS COCAINE METABOLITIES USING REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
JATLOW, PI ;
VANDYKE, C ;
BARASH, P ;
BYCK, R .
JOURNAL OF CHROMATOGRAPHY, 1978, 152 (01) :115-121
[5]  
JENKINS AJ, 1992, GC MS CONFIRMATION B
[6]   QUANTITATIVE-DETERMINATION OF BENZOYLECGONINE AND COCAINE IN HUMAN BIOFLUIDS BY GAS-LIQUID-CHROMATOGRAPHY [J].
KOGAN, MJ ;
VEREBEY, KG ;
DEPACE, AC ;
RESNICK, RB ;
MULE, SJ .
ANALYTICAL CHEMISTRY, 1977, 49 (13) :1965-1969
[7]   THIN-LAYER CHROMATOGRAPHY OF BENZOYLECGONINE - A RAPID QUALITATIVE METHOD FOR CONFIRMING THE EMIT URINE COCAINE METABOLITE ASSAYS [J].
KOGAN, MJ ;
PIERSON, DJ ;
DURKIN, MM ;
WILLSON, NJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 490 (01) :236-242
[8]  
LIU RH, 1989, J FORENSIC SCI, V34, P986
[9]  
MAJORS RE, 1992, LC GC-MAG SEP SCI, V10, P912
[10]   CONFIRMATION AND QUANTITATION OF COCAINE, BENZOYLECGONINE, ECGONINE METHYL-ESTER IN HUMAN-URINE BY GC MS [J].
MULE, SJ ;
CASELLA, GA .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1988, 12 (03) :153-155