CREATININE CLEARANCE IN RENAL DISEASE . A REAPPRAISAL

被引:132
作者
KIM, KE
ONESTI, G
RAMIREZ, O
BREST, AN
SWARTZ, C
机构
[1] Renal Research Laboratory, Department of Medicine, Hahnemann Medical College and Hospital, Philadelphia, Pennsylvania
[2] Division of Hypertension, Department of Medicine, Hahnemann Medical College and Hospital, Philadelphia, Pennsylvania
[3] Veterans Administration Hospital, San Juan
[4] Division of Cardiology, Department of Medicine, Jefferson Medical College Hospital, Philadelphia, Pennsylvania
[5] Department of Medicine, Hahnemann Medical College and Hospital, Philadelphia, Pennsylvania
关键词
D O I
10.1136/bmj.4.5674.11
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine the validity of endogenous creatinine clearance as a measure of glomerular filtration rate in patients with renal disease 308 simultaneous determinations of inulin clearance and endogenous creatinine clearance were reviewed and analysed. The ratio of creatinine clearance/inulin clearance increased progressively with the decline in inulin clearance, while the finding of a normal endogenous creatinine clearance masked a definite but mild decrease of glomerular filtration rate in 42% of the patients and a moderate decrease of glomerular filtration rate in 23%. This indicates that with declining glomerular filtration rates the endogenous creatinine clearance progressively overestimates actual glomerular filtration rates. Hence a single determination of creatinine clearance can be misleading as a screening measurement of glomerular filtration rate. © 1969, British Medical Journal Publishing Group. All rights reserved.