2ND-ORDER STEREOLOGY FOR PORES IN TRANSLUCENT ALUMINA STUDIED BY CONFOCAL SCANNING LASER MICROSCOPY

被引:16
作者
KARLSSON, LM [1 ]
LILJEBORG, A [1 ]
机构
[1] ROYAL INST TECHNOL, S-10044 STOCKHOLM, SWEDEN
关键词
ALUMINA; CONFOCAL MICROSCOPY; PORES; SPATIAL DISTRIBUTION; STEREOLOGY; STOCHASTIC GEOMETRY;
D O I
10.1111/j.1365-2818.1994.tb03484.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
The three-dimensional (3-D) arrangement of pores in translucent alumina was investigated with a confocal scanning laser microscope (CSLM). By moving the focal plane of the CSLM down into the material, a stack of serial thin optical sections was obtained to produce a 3-D image of the pores. Computer-based image analysis was used to obtain the coordinates of the pore centroids. The distance distribution function G(r) and the second-order functions K(r), L(r), H(r) and g(r) were used to analyse the spatial point pattern of the pore centroids. Estimates of the preceding functions obtained from eight stacks of sections were compared with the corresponding functions for a 3-D stationary Poisson point process, which served as a reference model for complete spatial randomness. The analysis suggested that the pore centroids were arranged in an aggregated pattern within a range of about 10 mu m.
引用
收藏
页码:186 / 194
页数:9
相关论文
共 26 条
[1]   STOCHASTIC GEOMETRY - AN INTRODUCTION AND READING-LIST [J].
BADDELEY, A .
INTERNATIONAL STATISTICAL REVIEW, 1982, 50 (02) :179-193
[2]  
Baddeley A, 1993, APPL STAT-J ROY ST C, V4, P641, DOI [DOI 10.2307/2986181, 10.2307/2986181]
[3]   A CAUTIONARY EXAMPLE ON THE USE OF 2ND-ORDER METHODS FOR ANALYZING POINT PATTERNS [J].
BADDELEY, AJ ;
SILVERMAN, BW .
BIOMETRICS, 1984, 40 (04) :1089-1093
[4]  
BADDELEY AJ, 1987, ACTA STEREOL S2, V6, P87
[5]   TANDEM SCANNING REFLECTED LIGHT-MICROSCOPY OF INTERNAL FEATURES IN WHOLE BONE AND TOOTH SAMPLES [J].
BOYDE, A ;
PETRAN, M ;
HADRAVSKY, M .
JOURNAL OF MICROSCOPY, 1983, 132 (OCT) :1-7
[6]   THE IMPACT OF RECENT STEREOLOGICAL ADVANCES ON QUANTITATIVE STUDIES OF THE NERVOUS-SYSTEM [J].
BRAENDGAARD, H ;
GUNDERSEN, HJG .
JOURNAL OF NEUROSCIENCE METHODS, 1986, 18 (1-2) :39-78
[7]   A CONFOCAL LASER MICROSCOPE SCANNER FOR DIGITAL RECORDING OF OPTICAL SERIAL SECTIONS [J].
CARLSSON, K ;
LILJEBORG, A .
JOURNAL OF MICROSCOPY-OXFORD, 1989, 153 :171-180
[8]   3-DIMENSIONAL MICROSCOPY USING A CONFOCAL LASER SCANNING MICROSCOPE [J].
CARLSSON, K ;
DANIELSSON, PE ;
LENZ, R ;
LILJEBORG, A ;
MAJLOF, L ;
ASLUND, N .
OPTICS LETTERS, 1985, 10 (02) :53-55
[9]  
Cruz-Orive LM, 1989, ACTA STEREOL, V8, P641
[10]   RECENT STEREOLOGICAL METHODS FOR CELL BIOLOGY - A BRIEF SURVEY [J].
CRUZORIVE, LM ;
WEIBEL, ER .
AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 258 (04) :L148-L156