A BIOMECHANICAL STUDY OF ODONTOID FRACTURES AND FRACTURE FIXATION

被引:80
作者
DOHERTY, BJ
HEGGENESS, MH
ESSES, SI
机构
[1] Baylor College of Medicine, Department of Orthopedic Surgery, Center for Spinal Disorders, Houston, TX
关键词
ODONTOID FRACTURE; MECHANISM; INTERNAL FIXATION;
D O I
10.1097/00007632-199302000-00002
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The purpose of this study was to measure the stability of the odontoid process after fracture and subsequent screw fixation. To accomplish this, we mechanically reproduced Type II and Type III odontoid fractures on isolated C2 vertebrae by varying the direction of load. These fractures were subsequently stabilized with a single 3.5 mm screw and retested for multidirectional stability and load to failure. Reduced and instrumented specimens were found to have a stiffness equivalent to one half of that of the unfractured odontoid. Load to failure was also slightly less than one half of the original fracture force (average 160 lb). Screw failure was by a cut-out mechanism in all Type III fractures and by bending of the screw in all Type III fractures. Our findings, in conjunction with the existing literature, strongly suggest that Type III fractures result from extension forces, whereas Type II fractures result from lateral or oblique loading forces. Single screw fixation of an odontoid fracture will provide stability equal to approximately one half that of the unfractured bone.
引用
收藏
页码:178 / 184
页数:7
相关论文
共 24 条
[1]  
Althoff B., Fracture of the Odontoid Process, Acta Orthop Scand Suppl, 177, pp. 3-94, (1979)
[2]  
Anderson L.D., D'Alonzo R.T., Fractures of the odontoid process of the axis, J Bone Joint Surg, 56A, pp. 1663-1674, (1974)
[3]  
Blockey N.J., Purser D.W., Fractures of the odontoid process of the axis, J Bone Joint Surg, 38B, pp. 794-816, (1956)
[4]  
Bohler J., Anterior stabilization for acute fractures and non-unions of the dens, J Bone Joint Surg, 64, pp. 18-28, (1982)
[5]  
Bohlman H.H., Acute fractures and dislocations of the cervical spine. An analysis of three hundred hospitalized patients and review of the literature, J Bone Joint Surg, 61A, (1979)
[6]  
Chan D., Morwessel R.M., Leung K., Treatment of odontoid fractures with halo cast immobilization, Orthop Trans, 5, pp. 118-119, (1981)
[7]  
Clark C.R., White A.A., Fractures of the dens: A multicenter study, J Bone Joint Surg, 67, pp. 1340-1348, (1985)
[8]  
Ekong C., Schwartz M.L., Tator C.H., Rowed D.W., Edmonds V.E., Odontoid fracture: Management with early mobilization using the halo device, Neurosurgery, 9, pp. 631-637, (1981)
[9]  
Esses S.I., Bednar D., Screw fixation of odontoid fractures and non-unions, Spine, 16, pp. S483-S485, (1991)
[10]  
Etter C., Coscia M., Jaberg H., Aebi M., Direct anterior fixation of dens fractures with a cannulated screw system, Spine, 16, pp. 25S-32S, (1991)