MEASUREMENTS OF POLYCAPILLARY X-RAY OPTICS

被引:33
作者
ULLRICH, JB
KOVANTSEV, V
MACDONALD, CA
机构
[1] Center for X-Ray Optics, University at Albany, SUNY, Albany
关键词
D O I
10.1063/1.355204
中图分类号
O59 [应用物理学];
学科分类号
摘要
Assemblies of hollow capillary tubes, termed ''Kumakhov optics,'' can be used to control x rays for a large variety of applications. Measurements of x-ray transmission in polycapillary glass tubes were performed for the purpose of understanding their behavior in such devices. X-ray transmission was measured for straight, uniformly curved, and nonuniformly bent fibers. The data agree well with a computer simulation based on classical ray tracing.
引用
收藏
页码:5933 / 5939
页数:7
相关论文
共 11 条
[1]  
[Anonymous], 1962, CLASSICAL ELECTRODYN
[2]  
ARKDEV VA, 1989, SOV PHYS USP, V32, P271
[3]  
Gibson W. M., 1991, TECHNOLOGY REQUIREME
[4]   X-RAY INTERACTIONS - PHOTOABSORPTION, SCATTERING, TRANSMISSION, AND REFLECTION AT E=50-30,000 EV, Z=1-92 [J].
HENKE, BL ;
GULLIKSON, EM ;
DAVIS, JC .
ATOMIC DATA AND NUCLEAR DATA TABLES, 1993, 54 (02) :181-342
[5]  
JENTZCH F, 1929, PHYS Z, V30, P1268
[6]   CHANNELING OF PHOTONS AND NEW X-RAY OPTICS [J].
KUMAKHOV, MA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 48 (1-4) :283-286
[7]   A POLYCAPILLARY-BASED X-RAY OPTICAL-SYSTEM FOR DIFFRACTION APPLICATIONS [J].
PANTOJAS, VM ;
KOVANTSEV, VE ;
PANT, J ;
BUDKOV, SA ;
HAYES, TM ;
PERSANS, PD .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 333 (2-3) :607-617
[8]   FOCUSING OF SYNCHROTRON RADIATION USING TAPERED GLASS-CAPILLARIES [J].
THIEL, DJ ;
STERN, EA ;
BILDERBACK, DH ;
LEWIS, A .
PHYSICA B, 1989, 158 (1-3) :314-316
[9]  
UNDERWOOD JH, 1984, PHYS TODAY, V34, P44
[10]  
VARTANIAN MH, 1993, ELECTRON BEAM XRAY I, V3, P335