40-100-MHZ B-SCAN ULTRASOUND BACKSCATTER MICROSCOPE FOR SKIN IMAGING

被引:159
作者
TURNBULL, DH
STARKOSKI, BG
HARASIEWICZ, KA
SEMPLE, JL
FROM, L
GUPTA, AK
SAUDER, DN
FOSTER, FS
机构
[1] TORONTO BAYVIEW REG CANC CTR, TORONTO, ON M4N 3M5, CANADA
[2] UNIV TORONTO, SUNNYBROOK HLTH SCI CTR, DEPT MED BIOPHYS, TORONTO, ON M4N 3M5, CANADA
[3] UNIV TORONTO, WOMENS COLL HOSP, DEPT SURG, TORONTO, ON, CANADA
[4] UNIV TORONTO, WOMENS COLL HOSP, DEPT PATHOL, TORONTO, ON, CANADA
[5] UNIV TORONTO, SUNNYBROOK HLTH SCI CTR, DEPT DERMATOL, TORONTO, ON, CANADA
关键词
ULTRASOUND BACKSCATTER MICROSCOPE; ULTRASOUND; HIGH FREQUENCY; HIGH RESOLUTION; SKIN IMAGING; NORMAL SKIN; SEBORRHEIC KERATOSIS; MELANOMA;
D O I
10.1016/0301-5629(94)00083-2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
There is a growing interest in high resolution, subsurface imaging of cutaneous tissues using higher frequency ultrasound, and several commercial systems have been developed recently which operate at 20 MHz. Some of the possible applications of higher frequency skin imaging include tumour staging, boundary definition, and studies of the response of tumours to therapy, investigations of inflammatory skin conditions such as psoriasis and eczema, and basic studies of skin aging, sun damage and the effects of irritants. Investigation of these areas is quite new, and the role of ultrasound skin imaging is continuing to evolve. Lateral resolution in the 20 MHz imaging systems ranges from 200 to 300 mu m, which limits imaging applications to cutaneous structures which are relatively large in size. In this paper, a real-time ultrasound backscatter microscope (UBM) for skin imaging is described which operates in the 40-100 MHz range, providing axial resolution between 17 and 30 mu m and lateral resolution between 33 and 94 mu m This improvement in resolution over current skin ultrasound systems should prove useful in determining the margins of small skin lesions, and in obtaining more precise, in vivo skin thickness measurements to characterize nonmalignant skin disease. Example images of normal skin, seborrhoeic keratosis and malignant melanoma illustrate the imaging potential of this system.
引用
收藏
页码:79 / 88
页数:10
相关论文
共 19 条
[1]   DETERMINING SKIN THICKNESS WITH PULSED ULTRA SOUND [J].
ALEXANDER, H ;
MILLER, DL .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1979, 72 (01) :17-19
[2]  
ALTMEYER P, 1992, ULTRASOUND DERMATOLO
[3]   HIGH-RESOLUTION REAL-TIME ULTRASONIC SCANNER [J].
BERSON, M ;
VAILLANT, L ;
PATAT, F ;
POURCELOT, L .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1992, 18 (05) :471-478
[4]  
El-Gammal S, 1992, ULTRASOUND DERMATOLO, P297
[5]   PRINCIPLES AND APPLICATIONS OF ULTRASOUND BACKSCATTER MICROSCOPY [J].
FOSTER, FS ;
PAVLIN, CJ ;
LOCKWOOD, GR ;
RYAN, LK ;
HARASIEWICZ, KA ;
BERUBE, L ;
RAUTH, AM .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (05) :608-617
[6]   DIAGNOSTIC HIGH-RESOLUTION ULTRASOUND IN DERMATOLOGY [J].
GROPPER, CA ;
STILLER, MJ ;
SHUPACK, JL ;
DRILLER, J ;
RORKE, M ;
LIZZI, F .
INTERNATIONAL JOURNAL OF DERMATOLOGY, 1993, 32 (04) :243-250
[7]   HIGH-FREQUENCY, HIGH-RESOLUTION B-SCAN ULTRASOUND IN THE ASSESSMENT OF SKIN TUMORS [J].
HARLAND, CC ;
BAMBER, JC ;
GUSTERSON, BA ;
MORTIMER, PS .
BRITISH JOURNAL OF DERMATOLOGY, 1993, 128 (05) :525-532
[8]   ULTRASOUND TRANSDUCERS FOR PULSE-ECHO MEDICAL IMAGING [J].
HUNT, JW ;
ARDITI, M ;
FOSTER, FS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (08) :453-481
[9]   THE USE OF ACOUSTIC MICROSCOPY FOR BIOLOGICAL TISSUE CHARACTERIZATION [J].
KOLOSOV, OV ;
LEVIN, VM ;
MAYEV, RG ;
SENJUSHKINA, TA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1987, 13 (08) :477-483
[10]   THE DESIGN OF PROTECTION CIRCUITRY FOR HIGH-FREQUENCY ULTRASOUND IMAGING-SYSTEMS [J].
LOCKWOOD, GR ;
HUNT, JW ;
FOSTER, FS .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1991, 38 (01) :48-55