MODEL EXPERIMENTS WITH INTEGRATED OPTICAL INPUT GRATING COUPLERS AS DIRECT IMMUNOSENSORS

被引:31
作者
NELLEN, PM
LUKOSZ, W
机构
[1] Optics Laboratory, Swiss Federal Institute of Technology
关键词
DIRECT OPTICAL IMMUNOSENSORS AND IMMUNOASSAYS; OPTICAL WAVE-GUIDES; INTEGRATED OPTICS; GRATING COUPLERS;
D O I
10.1016/0956-5663(91)85049-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Using an input grating coupler instrument and monomode optical waveguides, we studied the adsorption of various proteins (e.g. human immunoglobulins G and A (h-IgG and h-IgA), and avidin) on the waveguide surface. In model experiments for immunoassays, we also monitored as a function of time the formation of the immuno-complex Ag-Ab between antigen (Ag) molecules adsorbed on the waveguide surface and antibody (Ab) molecules, for example, of adsorbed h-IgG vs anti-h-IgG, anti-goat-IgG (cross-reaction) and anti-h-IgA (negative test). We also studied the affinity reaction between absorbed protein A and h-IgG. From the measured changes in the effective refractive indices N(TE0) and N(TM0) of the TE0 and TM0 modes, we determined the thickness d(F'), the refractive index n(F'), and the surface coverage GAMMA of the adsorbed protein adlayers and of the immuno-complexes.
引用
收藏
页码:517 / 525
页数:9
相关论文
共 9 条
[1]   OPTICAL-PROPERTIES OF THIN-LAYERS OF BOVINE SERUM-ALBUMIN, GAMMA-GLOBULIN, AND HEMOGLOBIN [J].
ARWIN, H .
APPLIED SPECTROSCOPY, 1986, 40 (03) :313-318
[2]  
BJORK I, 1972, European Journal of Biochemistry, V29, P579, DOI 10.1111/j.1432-1033.1972.tb02024.x
[3]   ELLIPSOMETRY AS A TOOL TO STUDY ADSORPTION BEHAVIOR OF SYNTHETIC AND BIOPOLYMERS AT AIR-WATER-INTERFACE [J].
DEFEIJTER, JA ;
BENJAMINS, J ;
VEER, FA .
BIOPOLYMERS, 1978, 17 (07) :1759-1772
[4]  
IVARSSON B, 1986, CRIT REV BIOCOMPAT, V2, P1
[5]   OUTPUT GRATING COUPLERS ON PLANAR OPTICAL WAVE-GUIDES AS DIRECT IMMUNOSENSORS [J].
LUKOSZ, W ;
CLERC, D ;
NELLEN, PM ;
STAMM, C ;
WEISS, P .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (03) :227-232
[6]  
LUKOSZ W, 1991, BIOSENS BIOELECTRON, V6
[7]   INTEGRATED OPTICAL INPUT GRATING COUPLERS AS BIOCHEMICAL SENSORS [J].
NELLEN, PM ;
TIEFENTHALER, K ;
LUKOSZ, W .
SENSORS AND ACTUATORS, 1988, 15 (03) :285-295
[8]   INTEGRATED OPTICAL INPUT GRATING COUPLERS AS CHEMOSENSORS AND IMMUNOSENSORS [J].
NELLEN, PM ;
LUKOSZ, W .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) :592-596
[9]   HYDRODYNAMIC PROPERTIES OF BOVINE SERUM ALBUMIN MONOMER AND DIMER [J].
SQUIRE, PG ;
MOSER, P ;
OKONSKI, CT .
BIOCHEMISTRY, 1968, 7 (12) :4261-+