STUDIES OF HELIUM GAS-MIXTURES FOR LOW MASS TRACKING DETECTORS

被引:12
作者
PLAYFER, SM
BERNET, R
EICHLER, R
STAMPFLI, B
机构
[1] Institut für Mittelenergiephysik, ETH Zürich
关键词
D O I
10.1016/0168-9002(92)90753-Q
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Helium gas mixtures can improve tracking resolution for particles below 1 GeV/c because of the reduction in multiple scattering. We have measured the drift velocity and spatial resolution of several interesting mixtures including helium:DME and helium:CO2:isobutane. We discuss the advantages and disadvantages of using such a gas mixture for a detector at a B-meson factory, and conclude that helium:DME (80:20) and (70:30) mixtures will give significantly improved momentum resolution. The low drift velocity in such mixtures is a disadvantage in a high rate environment, but this is partly compensated by a low sensitivity to synchrotron radiation background.
引用
收藏
页码:494 / 501
页数:8
相关论文
共 16 条
[1]   RELATIVISTIC CHARGED-PARTICLE IDENTIFICATION BY ENERGY-LOSS [J].
ALLISON, WWM ;
COBB, JH .
ANNUAL REVIEW OF NUCLEAR AND PARTICLE SCIENCE, 1980, 30 :253-298
[2]  
BURCHAT P, 1990, CONTRIBUTION WORKSHO
[3]   DESIGN AND CONSTRUCTION OF THE CLEO-II DRIFT CHAMBER [J].
CASSEL, DG ;
DESALVO, R ;
DOBBINS, J ;
GILCHRIESE, MGD ;
GRAY, S ;
HARTILL, D ;
MUELLER, J ;
PETERSON, D ;
PISHARODY, M ;
RILEY, D ;
KINOSHITA, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 252 (2-3) :325-330
[4]   TEST OF A HIGH-RESOLUTION DRIFT CHAMBER PROTOTYPE [J].
COMMICHAU, V ;
DEUTSCHMANN, M ;
DRAHEIM, KJ ;
FRITZE, P ;
HANGARTER, K ;
HAWELKA, P ;
HERTEN, U ;
LINNHOFER, D ;
TONUTTI, M ;
BIERMANN, U ;
RODERBURG, E ;
WALENTA, AH ;
ANDERHUB, H ;
FEHLMANN, J ;
HOFER, H ;
KLEIN, M ;
PARADISO, JA ;
SCHREIBER, J ;
VIERTEL, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 235 (02) :267-278
[5]  
FEHLMANN J, 1983, WIRCHA PROGRAM PACKA
[6]   UNCERTAINTIES IN TRACK MOMENTUM AND DIRECTION, DUE TO MULTIPLE SCATTERING AND MEASUREMENT ERRORS [J].
GLUCKSTERN, RL .
NUCLEAR INSTRUMENTS & METHODS, 1963, 24 (04) :381-389
[7]   A CENTRAL TRACKING DETECTOR FOR A B-FACTORY [J].
GRANCAGNOLO, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 277 (01) :110-115
[8]  
KAPITZA H, 1991, COMMUNICATION
[9]  
MAARTENS K, 1989, THESIS HEIDELBERG
[10]   FLUCTUATIONS OF IONIZATION LOSSES IN PROPORTIONAL CHAMBERS [J].
ONUCHIN, AP ;
TELNOV, VI .
NUCLEAR INSTRUMENTS & METHODS, 1974, 120 (02) :365-368