DETECTION OF CIRCULATING CEREBRAL EMBOLI USING DOPPLER ULTRASOUND IN A SHEEP MODEL

被引:46
作者
MARKUS, H [1 ]
LOH, A [1 ]
BROWN, MM [1 ]
机构
[1] ST GEORGE HOSP,SCH MED,DEPT SURG,LONDON SW17 0RE,ENGLAND
关键词
CEREBROVASCULAR DISEASE; CEREBRAL EMBOLISM; ULTRASONICS;
D O I
10.1016/0022-510X(94)90061-2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We describe a validation study of a new technique for detecting circulating pathological cerebral emboli. Theoretically one would expect sold emboli to be detectable as high intensity signals on the Doppler waveform, and such signals have been reported in humans with potential embolic sources. Pathological cerebral emboli (thrombi, platelet aggregates and atheroma) were introduced into the proximal carotid artery of an in vivo sheep model, and their passage detected in the cerebral circulation using Doppler ultrasound. All of 74 emboli, with a maximum dimension as small as 0.24 mm, were detected as short duration high intensity signals. Smaller pathological emboli could not be made but glass microspheres as small as 5-20 micron resulted in high intensity signals. A significant positive correlation was found between embolus size and relative intensity increase of the embolic signal. A significant positive correlation was also found between embolus size and duration of embolic signal. This study demonstrates that detection of circulating cerebral emboli is possible in vivo. This technique may allow selection of patients at particularly high risk of cerebral embolisation so that they can be given specific prophylactic treatment. Analysis of the Doppler signal may give information on the size of the embolus, although using current signal analysis it is impossible to distinguish between the signals produced by say a larger platelet embolus or a smaller thrombus embolus.
引用
收藏
页码:117 / 124
页数:8
相关论文
共 13 条
[1]  
AUSTEN WG, 1965, J SURG RES, V5, P283
[2]   STROKE PREVENTION IN ATRIAL-FIBRILLATION TRIAL [J].
CAIRNS, JA .
CIRCULATION, 1991, 84 (02) :933-935
[3]  
COWBURN P J, 1992, Clinical Science (London), V82, p1P
[4]   COMPUTERIZED DETECTION OF CEREBRAL EMBOLI AND DISCRIMINATION FROM ARTIFACT USING DOPPLER ULTRASOUND [J].
MARKUS, H ;
LOH, A ;
BROWN, MM .
STROKE, 1993, 24 (11) :1667-1672
[5]  
MARKUS HS, 1993, STROKE, V24, P1
[6]   MICROEMBOLI AND CEREBRAL IMPAIRMENT DURING CARDIAC-SURGERY [J].
PUGSLEY, W ;
KLINGER, L ;
PASCHALIS, C ;
ASPEY, B ;
NEWMAN, S ;
HARRISON, M ;
TREASURE, T .
VASCULAR SURGERY, 1990, 24 (01) :34-43
[7]   DETECTION OF ARTERIAL EMBOLI USING DOPPLER ULTRASOUND IN RABBITS [J].
RUSSELL, D ;
MADDEN, KP ;
CLARK, WM ;
SANDSET, PM ;
ZIVIN, JA .
STROKE, 1991, 22 (02) :253-258
[8]   DETECTION OF INTRACRANIAL EMBOLI IN PATIENTS WITH SYMPTOMATIC EXTRACRANIAL CAROTID-ARTERY DISEASE [J].
SIEBLER, M ;
SITZER, M ;
STEINMETZ, H .
STROKE, 1992, 23 (11) :1652-1654
[9]  
SPENCER MP, 1969, JOM-J OCCUP MED, V11, P238
[10]   DETECTION OF MIDDLE CEREBRAL-ARTERY EMBOLI DURING CAROTID ENDARTERECTOMY USING TRANSCRANIAL DOPPLER ULTRASONOGRAPHY [J].
SPENCER, MP ;
THOMAS, GI ;
NICHOLLS, SC ;
SAUVAGE, LR .
STROKE, 1990, 21 (03) :415-423