SUPPORTED HIGH-RISK CORONARY ANGIOPLASTY USING INTRAAORTIC BALLOON PUMP COUNTERPULSATION

被引:67
作者
KAHN, JK
RUTHERFORD, BD
MCCONAHAY, DR
JOHNSON, WL
GIORGI, LV
HARTZLER, GO
机构
[1] CARDIOVASC CONSULTANTS INC,4320 WORNALL RD,MED PLAZA 2-20,KANSAS CITY,MO 64111
[2] ST LUKES HOSP,MID AMER HEART INST,KANSAS CITY,MO 64111
关键词
D O I
10.1016/0735-1097(90)90257-P
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Hemodynamic support may be desirable for selected patients with high risk characteristics undergoing elective coronary angioplasty. Twenty-eight high risk patients were studied with elective intraaortic balloon pump support over a recent 30 month period. Their mean age was 66 years; 10 patients were ≥70 years old. Class III or IV angina was present in 23 patients (82%). The mean left ventricular ejection fraction was 24% (range 15% to 50%) and was <30% in 25 patients (89%). Three vessel disease was present in 26 patients (93%) and 7 patients had significant left main coronary artery disease. Ninety (96%) of 94 attempts to dilate stenoses were successful, including multivessel angioplasty in 21 patients (75%) and five left main coronary artery dilations. Decreases in systolic blood pressure to ≤70 mm Hg occurred in 11 patients (39%), but augmented diastolic pressure was ≥90 mm Hg at all times. No deaths or myocardial infarctions occurred within 72 h of coronary angioplasty. Vascular complications requiring surgical repair occurred in three patients who had good operative results and no need for transfusions. Thus, intraaortic balloon pump support in patients with high risk features undergoing elective coronary angioplasty appears effective and relatively benign, although definite benefit cannot be proved without a randomized study. Newer techniques, such as in-laboratory cardiopulmonary bypass, must be compared with the results obtained with intraaortic balloon pump support alone. © 1990.
引用
收藏
页码:1151 / 1155
页数:5
相关论文
共 22 条
[1]   THE ROLE OF INTRA-AORTIC BALLOON COUNTERPULSATION IN PATIENTS UNDERGOING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
ALCAN, KE ;
STERTZER, SH ;
WALLSH, E ;
DEPASQUALE, NP ;
BRUNO, MS .
AMERICAN HEART JOURNAL, 1983, 105 (03) :527-530
[2]   PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY IN 1985-1986 AND 1977-1981 - THE NATIONAL-HEART-LUNG-AND-BLOOD-INSTITUTE REGISTRY [J].
DETRE, K ;
HOLUBKOV, R ;
KELSEY, S ;
COWLEY, M ;
KENT, K ;
WILLIAMS, D ;
MYLER, R ;
FAXON, D ;
HOLMES, D ;
BOURASSA, M ;
BLOCK, P ;
GOSSELIN, A ;
BENTIVOGLIO, L ;
LEATHERMAN, L ;
DORROS, G ;
KING, S ;
GALICHIA, J ;
ALBASSAM, M ;
LEON, M ;
ROBERTSON, T ;
PASSAMANI, E .
NEW ENGLAND JOURNAL OF MEDICINE, 1988, 318 (05) :265-270
[3]   INTRAAORTIC BALLOON PUMP INSERTION - A RANDOMIZED STUDY COMPARING PERCUTANEOUS AND SURGICAL TECHNIQUES [J].
GOLDBERG, MJ ;
RUBENFIRE, M ;
KANTROWITZ, A ;
GOODMAN, G ;
FREED, PS ;
HALLEN, L ;
REIMANN, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (03) :515-523
[4]   HIGH-RISK PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
HARTZLER, GO ;
RUTHERFORD, BD ;
MCCONAHAY, DR ;
JOHNSON, WL ;
GIORGI, LV .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (14) :G33-G37
[5]   COMPLEX CORONARY ANGIOPLASTY - AN ALTERNATIVE THERAPY [J].
HARTZLER, GO .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1985, 9 (02) :133-137
[6]  
HARTZLER GO, 1986, PRACTICE CORONARY AN, P250
[7]   FAILURE OF INTRAAORTIC BALLOON COUNTERPULSATION TO AUGMENT DISTAL CORONARY PERFUSION-PRESSURE DURING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
MACDONALD, RG ;
HILL, JA ;
FELDMAN, RL .
AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (04) :359-361
[8]   LEFT MAIN CORONARY ANGIOPLASTY - EARLY AND LATE RESULTS OF 127 ACUTE AND ELECTIVE PROCEDURES [J].
OKEEFE, JH ;
HARTZLER, GO ;
RUTHERFORD, BD ;
MCCONAHAY, DR ;
JOHNSON, WL ;
GIORGI, LV ;
LIGON, RW .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (03) :144-147
[9]   PERCUTANEOUS CARDIOPULMONARY BYPASS - APPLICATION AND INDICATION FOR USE [J].
PHILLIPS, SJ ;
ZEFF, RH ;
KONGTAHWORN, C ;
SKINNER, JR ;
TOON, RS ;
GRIGNON, A ;
KENNERLY, RM ;
WICKEMEYER, W ;
IANNONE, LA .
ANNALS OF THORACIC SURGERY, 1989, 47 (01) :121-123
[10]   MYOCARDIAL PROTECTION DURING CORONARY ANGIOPLASTY WITH AN AUTOPERFUSION BALLOON CATHETER IN HUMANS [J].
QUIGLEY, PJ ;
HINOHARA, T ;
PHILLIPS, HR ;
PETER, RH ;
BEHAR, VS ;
KONG, YH ;
SIMONTON, CA ;
PEREZ, JA ;
STACK, RS .
CIRCULATION, 1988, 78 (05) :1128-1134