SURFACE MODIFICATION OF POLY(LACTIDE-CO-GLYCOLIDE) NANOSPHERES BY BIODEGRADABLE POLY(LACTIDE)-POLY(ETHYLENE GLYCOL) COPOLYMERS

被引:271
作者
STOLNIK, S
DUNN, SE
GARNETT, MC
DAVIES, MC
COOMBES, AGA
TAYLOR, DC
IRVING, MP
PURKISS, SC
TADROS, TF
DAVIS, SS
ILLUM, L
机构
[1] UNIV NOTTINGHAM,DEPT PHARMACEUT SCI,NOTTINGHAM NG7 2RD,ENGLAND
[2] ZENECA PHARMACEUT,MACCLESFIELD,CHESHIRE,ENGLAND
关键词
POLY(LACTIDE)-POLY(ETHYLENE GLYCOL) COPOLYMERS; POLY(LACTIDE-CO-GLYCOLIDE); BIODEGRADABLE; NANOSPHERES; STERIC STABILIZATION; SURFACE CHARACTERIZATION; BIODISTRIBUTION; BLOOD CLEARANCE;
D O I
10.1023/A:1018931820564
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The modification of surface properties of biodegradable poly(lactide-co-glycolide) (PLGA) and model polystyrene nanospheres by poly(lactide)-poly(ethlene glycol) (PLA:PEG) copolymers has been assessed using a range of in vitro characterization methods followed by in vivo studies of the nanospheres biodistribution after intravenous injection into rats. Coating polymers with PLA:PEG ratio of 2:5 and 3:4 (PEG chains of 5000 and 2000 Da, respectively) were studied. The results reveal the formation of a PLA:PEG coating layer on the particle surface resulting in an increase in the surface hydrophilicity and decrease in the surface charge of the nanospheres. The effects of addition of electrolyte and changes in pH on stability of the nanosphere dispersions confirm that uncoated particles are electrostatically stabilized, while in the presence of the copolymers, steric repulsions are responsible for the stability. The PLA:PEG coating also prevented albumin adsorption onto the colloid surface. The evidence that this effect was observed for the PLA:PEG 3:4 coated nanospheres may indicate that a poly(ethylene glycol) chain of 2000 Da can provide an effective repulsive barrier to albumin adsorption. The in vivo results reveal that coating of PLGA nanospheres with PLA:PEG copolymers can alter the biodistribution in comparison to uncoated PLGA nanospheres. Coating of the model polystyrene nanospheres with PLA:PEG copolymers resulted in an initial high circulation level, but after 3 hours the organ deposition data showed values similar to uncoated polystyrene spheres. The difference in the biological behaviour of coated PLGA and polystyrene nanospheres may suggest a different stability of the adsorbed layers on these two systems. A similar biodistribution pattern of PLA:PEG 3:4 to PEG 2:5 coated particles may indicate that poly(ethylene glycol) chains in the range of 2000 to 5000 can produce a comparable effect on in vivo behaviour.
引用
收藏
页码:1800 / 1808
页数:9
相关论文
共 29 条
[1]  
CHURCHILL JR, 1983, Patent No. 92918
[2]  
CUMMINS HZ, 1974, NATO ASI SERIES
[3]   PARTICLE-SIZE AND SIZE DISTRIBUTION OF POLY(BUTYL-2-CYANOACRYLATE) NANOPARTICLES .1. INFLUENCE OF PHYSICOCHEMICAL FACTORS [J].
DOUGLAS, SJ ;
ILLUM, L ;
DAVIS, SS ;
KREUTER, J .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1984, 101 (01) :149-158
[4]  
Golander C. G., 1992, POLYETHYLENE GLYCOL, P221, DOI DOI 10.1007/978-1-4899-0703-5_15.
[5]  
Gombotz W.R, 1992, POLYETHYLENE GLYCOL, P249
[6]  
Gref R, 1993, P INT S CONTROL REL, V20, P131
[7]  
HUH Y, 1974, RADIAT RES, V60, P42, DOI 10.2307/3574004
[8]   SURFACE CHARACTERISTICS AND THE INTERACTION OF COLLOIDAL PARTICLES WITH MOUSE PERITONEAL-MACROPHAGES [J].
ILLUM, L ;
JACOBSEN, LO ;
MULLER, RH ;
MAK, E ;
DAVIS, SS .
BIOMATERIALS, 1987, 8 (02) :113-117
[9]   THE ORGAN DISTRIBUTION AND CIRCULATION TIME OF INTRAVENOUSLY INJECTED COLLOIDAL CARRIERS STERICALLY STABILIZED WITH A BLOCKCOPOLYMER - POLOXAMINE 908 [J].
ILLUM, L ;
DAVIS, SS ;
MULLER, RH ;
MAK, E ;
WEST, P .
LIFE SCIENCES, 1987, 40 (04) :367-374
[10]   THE EFFECT OF STABILIZING AGENTS ON THE ORGAN DISTRIBUTION OF LIPID EMULSIONS [J].
ILLUM, L ;
WEST, P ;
WASHINGTON, C ;
DAVIS, SS .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1989, 54 (01) :41-49