THE CALCULATION OF TRANSMISSION THROUGH A PHOTON-BEAM ATTENUATOR USING SECTOR INTEGRATION

被引:11
作者
PAPIEZ, E [1 ]
FROESE, G [1 ]
机构
[1] UNIV MANITOBA,DEPT PHYS,WINNIPEG R3T 2N2,MANITOBA,CANADA
关键词
broad-beam transmission; lead attenuators;
D O I
10.1118/1.596507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A calculational scheme is presented for the prediction of the transmitted fraction (TR) through an attenuator of known material and physical dimensions, at any point in a photon beam, for a beam of any shape or size. The method considers the total TR to be composed of scatter and primary components and computes the scatter component by sector integration. The input for the calculations consists of measured narrow- and broad-beam transmitted fractions through lead in air for various circular fields, thicknesses of the attenuator, and angles from the central axis, in a geometry approximating typical treatment conditions. The method has been tested for the case of a uniform half slab and a 45° wedge in a 4-MV photon beam. It was found that the use of TR values obtained by the above method reduced the maximum absorbed dose computation error from 8% computed with a commercially available algorithm to 3%, in a typical treatment setup. This method is generally applicable to any shaped attenuator such as a wedge or compensator covering whole or part of a radiation field. © 1990, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:281 / 286
页数:6
相关论文
共 13 条
[1]  
Clarkson JR., 1941, BRIT J RADIOL, V14, P265, DOI DOI 10.1259/0007-1285-14-164-265
[2]  
CUNNINGHAM J R, 1972, Computer Programs in Biomedicine, V2, P192, DOI 10.1016/0010-468X(72)90029-3
[3]   SCATTER-AIR RATIOS [J].
CUNNINGHAM, JR .
PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (01) :42-+
[4]  
DYK JV, 1986, MED PHYS, V13, P105
[5]   THE EFFECT OF LEAD ATTENUATORS ON DOSE IN HOMOGENEOUS PHANTOMS [J].
ELKHATIB, EE ;
PODGORSAK, EB ;
PLA, C .
MEDICAL PHYSICS, 1986, 13 (06) :928-935
[6]   SCATTERED PHOTONS PRODUCED BY BEAM-MODIFYING FILTERS [J].
HUANG, PH ;
CHIN, LM ;
BJARNGARD, BE .
MEDICAL PHYSICS, 1986, 13 (01) :57-63
[7]   RECONSTRUCTION OF 4-MV BREMSSTRAHLUNG SPECTRA FROM MEASURED TRANSMISSION DATA [J].
HUANG, PH ;
KASE, KR ;
BJARNGARD, BE .
MEDICAL PHYSICS, 1983, 10 (06) :778-785
[8]   METHOD OF LARGE IRREGULAR FIELD COMPENSATION [J].
LEUNG, PMK ;
VANDYK, J ;
ROBINS, J .
BRITISH JOURNAL OF RADIOLOGY, 1974, 47 (563) :805-810
[9]   ENERGY AND ANGULAR-DISTRIBUTIONS OF PHOTONS FROM MEDICAL LINEAR ACCELERATORS [J].
MOHAN, R ;
CHUI, C ;
LIDOFSKY, L .
MEDICAL PHYSICS, 1985, 12 (05) :592-597
[10]   FIELD SIZE DEPENDENCE OF WEDGE FACTORS [J].
PALTA, JR ;
DAFTARI, I ;
SUNTHARALINGAM, N .
MEDICAL PHYSICS, 1988, 15 (04) :624-628