SINGLE PHOTON RADIOLUMINESCENCE .1. THEORY AND SPECTROSCOPIC PROPERTIES

被引:9
作者
BICKNESE, S
SHAHROKH, Z
SHOHET, SB
VERKMAN, AS
机构
[1] UNIV CALIF SAN FRANCISCO,INST CANC RES,DEPT MED & PHYSIOL,SAN FRANCISCO,CA 94143
[2] UNIV CALIF SAN FRANCISCO,CARDIOVASC RES INST,SAN FRANCISCO,CA 94143
关键词
D O I
10.1016/S0006-3495(92)81720-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The excitation of a fluorescent molecule by a beta-decay electron (radioluminescence) depends upon the electron energy, the distance between radioactive 'donor' and fluorescent 'acceptor', and the excitation characteristics and solvent environment of the fluorophore. The theory for calculation of single photon radioluminescence (SPR) signals is developed here; in the accompanying paper, measurement methods and biological applications are presented. To calculate the three-dimensional spatial profile for electron energy deposition in an aqueous environment, a Monte Cado calculation was performed incorporating theories of electron energy distributions, energy loss due to interactions with matter, and deflections in electron motion due to collisions. For low energy beta emitters, 50% of energy deposition occurs within 0.63 mum (H-3, 18.5 keV), 22 mum (C-14, 156 keV), 25 mum (S-35, 167 keV), and 260 mum (Cl-36, 712 keV) of the radioisotope. In close proximity to the beta emitter (100 nm, H-3; 10 muM, C-14) the probability for fluorophore excitation is approximately proportional to the inverse square of the distance between the beta emitter and fluorophore. To investigate the other factors that determine the probability for fluorophore excitation, SPR measurements were carried out in solutions containing 3H and a series of fluorophores in different solvents. In water, the probability of fluorescence excitation was nearly proportional to the integrated absorbance over a > 1,000-fold variation in absorbances. The probability of fluorescence excitation was enhanced up to 2,600-fold when the fluorophore was in a "scintillant" aromatic or hydrocarbon solvent. SPR emission spectra were similar to fluorescence emission spectra obtained with photon excitation. The single photon signal due to Bremsstrahlung increased with wavelength in agreement with theory. The distance dependence for the SPR signal predicted by the model was in good agreement with measurements in which a C-14 donor was separated by known thicknesses of water from a fluorescently-coated coverglass. Quantitative predictions for radioluminescence signal as a function of donor-acceptor distance were developed for specific radioisotope-fluorophore geometries in biological samples.
引用
收藏
页码:1256 / 1266
页数:11
相关论文
共 20 条
[1]  
ALMOND PR, 1976, CLIN APPLICATIONS EL, P7
[2]  
Berger MJ., 1963, METHODS COMPUT PHYS, P135
[3]  
BERGER MJ, 1982, NBSIR822451 PUBL, P1
[4]  
BETHE H, 1953, EXPT NUCL PHYS, P166
[5]  
BLANCHARD CH, 1951, PHYS REV, V82, P767
[6]   SCINTILLATION PROXIMITY ASSAY [J].
BOSWORTH, N ;
TOWERS, P .
NATURE, 1989, 341 (6238) :167-168
[7]  
DEMAS JN, 1983, EXCITD STATE MEASURE, P213
[8]  
Evans R. D., 1955, ATOMIC NUCLEUS, P536
[9]  
Goldstein J. I., 1981, SCANNING ELECT MICRO, P53
[10]  
HIRAYAMA F, 1971, ORGANIC SCINTILLATOR, P205