TRANSESOPHAGEAL DOBUTAMINE STRESS ECHOCARDIOGRAPHY IN THE EVALUATION OF CORONARY-ARTERY DISEASE

被引:25
作者
FROHWEIN, S [1 ]
KLEIN, JL [1 ]
LANE, A [1 ]
TAYLOR, WR [1 ]
机构
[1] EMORY UNIV, SCH MED, DIV CARDIOL, ATLANTA, GA 30322 USA
关键词
D O I
10.1016/0735-1097(94)00464-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The goal of this study was to determine the feasibility safety, sensitivity and specificity of transesophageal debutamine stress echocardiography for the detection of coronary artery disease. Background. Dobutamine stress echocardiography has been shown to be an extremely sensitive and specific noninvasive technique for the detection of myocardial ischemia. However, inadequate transthoracic images preclude the use of dobutamine stress echocardiography in a small but significant group of patients. Transesophageal echocardiography provides better resolution than that obtained with routine transthoracic imaging. Methods. Patients scheduled for routine cardiac catheterization undenvent transesophageal dobutamine stress echocardiography. All patients undenvent coronary arteriography within 48 h of the study, and lesion severity,vas determined by quantitative coronary angiography, Significant coronary obstruction was defined as stenosis > 50%. Results. Fifty-one male patients were enrolled in the study; six were excluded for technical reasons, There were no adverse outcomes or complications. Of 27 patients with significant coronary artery disease, 22 had positive study results (sensitivity 82%). Of 13 patients without significant obstructive coronary disease, 1 had a false positive study result (specificity 93%). In patients,vith a minimal lumen diameter < 1.25 mm, sensitivity was > 80%, and in patients with a minimal lumen diameter > 1.5 mm, sensitivity was < 70%, suggesting that lesions with a minimal lumen diameter < 1.25 mm are more likely to be physiologically significant. Conclusions. Transesophageal dobutamine stress echocardiography is a feasible, safe and accurate technique for the detection of myocardial ischemia. There are inherent limitations to this technique in that transesophageal echocardiography must be performed. Transesophageal dobutamine stress echocardiography may allow extension of dobutamine stress testing to patients with inadequate transthoracic echocardiographic imaging and may provide an opportunity for further research applications.
引用
收藏
页码:823 / 829
页数:7
相关论文
共 38 条
[1]  
Armstrong, Stress echocardiography for detection of coronary artery disease, Circulation, 84, (1991)
[2]  
Sawada, Segar, Ryan, Et al., Echocardiographic detection of coronary artery disease during dobutamine infusion, Circulation, 83, pp. 1605-1614, (1991)
[3]  
Mazeika, Nadazdin, Oakley, Dobutamine stress echocardiography for detection and assessment of coronary artery disease, J Am Coll Cardiol, 19, pp. 1203-1211, (1992)
[4]  
Cohen, Greene, Ottenweller, Dobutamine digital echocardiography for detecting coronary artery disease, Am J Cardiol, 67, pp. 1311-1318, (1991)
[5]  
Mertes, Sawada, Ryan, Et al., Symptoms, adverse effects, and complications associated with dobutamine stress echocardiography, Circulation, 88, pp. 15-19, (1993)
[6]  
Smith, Cahalan, Benefiel, Et al., Intraoperative detection of myocardial ischemia in high-risk patients: electrocardiography versus two-dimensional transesophageal echocardiography, Circulation, 72, pp. 1015-1021, (1985)
[7]  
Topol, Weiss, Guzman, Et al., Immediate improvement of dysfunctional myocardial segments after coronary revascularization: detection by intraoperative transesophageal echocardiography, J Am Coll Cardiol, 4, pp. 1123-1134, (1984)
[8]  
Beaupre, Kremer, Cahalan, Lurz, Schiller, Hamilton, Intraoperative detection of changes in left ventricular segmental wall motion by transesophageal two dimensional echocardiography, Am Heart J, 107, pp. 1021-1023, (1984)
[9]  
Cohen, Ottenweller, George, Duvvuri, Comparison of dobutamine and exercise echocardiography for detecting coronary artery disease, Am J Cardiol, 72, pp. 1226-1231, (1993)
[10]  
Herman, LaBresh, Santos-Ocampo, Et al., Comparison of dobutamine and exercise using technetium-99m sestamibi imaging for the evaluation of coronary artery disease, Am J Cardiol, 73, pp. 164-169, (1994)