QUANTITATION OF FORMALDEHYDE, ACETALDEHYDE, AND ACETONE IN SIDESTREAM CIGARETTE-SMOKE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:53
作者
RISNER, CH
MARTIN, P
机构
[1] R.J. Reynolds Tobacco Co, Winston-Salem, NC
关键词
D O I
10.1093/chromsci/32.3.76
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method is described for the collection and quantitation of formaldehyde, acetaldehyde, and acetone in sidestream cigarette smoke. Using the 'fishtail' chimney procedure (1), sidestream smoke is drawn by vacuum through the chimney, a Cambridge filter pad (Performance Systematics Inc.; Caledonia, MI), and into an impinger containing a solution of 2,4-dinitrophenthydrazine (DNPH), whose solubility in acetonitrile was increased by using diglyme as a constituent of the collection derivatization solution. The chimney is rinsed with DNPH solution to remove 'formaldehyde', and the rinse is added to the impinger solution. This combined wash and impinger solution is used to extract the Cambridge pad. An aliquot of the extract is analyzed by high-performance liquid chromatography using a reversed-phase column, ultraviolet detection, and a mobile phase gradient with tetrahydrofuran as a modifier. Acrolein is detected but gives poor precision and recovery because of dimer formation. For formaldehyde, acetaldehyda, and acetone, both the precision (7.30, 2.49, 2.88% relative standard deviation, respectively) and recovery (90.0, 95.2, 102.8%, respectively) are acceptable. The response for formaldehyde, acetaldehyde, and acetone is linear and a function of the number of cigarette smoked. The minimum detectable quantity for the analytes ranges from 5 to 16 μg per cigarette.
引用
收藏
页码:76 / 82
页数:7
相关论文
共 22 条
[1]  
BELL JH, 1987, TOBACCO CHEM RES C
[2]   EFFECT OF PH ON THE REACTION OF 2,4-DINITROPHENYLHYDRAZINE WITH FORMALDEHYDE AND ACETALDEHYDE [J].
BICKING, MKL ;
COOKE, WM ;
KAWAHARA, FK ;
LONGBOTTOM, JE .
JOURNAL OF CHROMATOGRAPHY, 1988, 455 :310-315
[3]   A COMPARISON OF 3 DIFFERENT HIGH-PRESSURE LIQUID-CHROMATOGRAPHY SYSTEMS FOR THE DETERMINATION OF ALDEHYDES AND KETONES IN DIESEL EXHAUST .1. [J].
CREECH, G ;
JOHNSON, RT ;
STOFFER, JO .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1982, 20 (02) :67-72
[4]  
DREYFORS JM, 1989, AM IND HYG ASSOC J, V50, P579, DOI 10.1202/0002-8894(1989)050<0579:HAR>2.0.CO
[5]  
2
[6]  
HARRELL TG, 1975, TOBACCO SCI, V19, P145
[7]  
Hess LH, 1978, KIRKOTHMER ENCY CHEM, V1, P277
[8]   DETERMINATION OF FORMALDEHYDE AND ACETALDEHYDE IN MAINSTREAM CIGARETTE-SMOKE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HOULGATE, PR ;
DHINGRA, KS ;
NASH, SJ ;
EVANS, WH .
ANALYST, 1989, 114 (03) :355-360
[9]   DETERMINATION OF CARBONYL 2,4-DINITROPHENYLHYDRAZONES BY LIQUID CHROMATOGRAPHY/ELECTROCHEMISTRY [J].
JACOBS, WA ;
KISSINGER, PT .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1982, 5 (04) :669-676
[10]   DETERMINATION OF PICOMOLAR CONCENTRATIONS OF CARBONYL-COMPOUNDS IN NATURAL-WATERS, INCLUDING SEAWATER, BY LIQUID-CHROMATOGRAPHY [J].
KIEBER, RJ ;
MOPPER, K .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1990, 24 (10) :1477-1481