DETERMINATION OF BORON USING MANNITOL-ASSISTED ELECTROTHERMAL VAPORIZATION FOR SAMPLE INTRODUCTION IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY

被引:26
作者
WEI, WC [1 ]
CHEN, CJ [1 ]
YANG, MH [1 ]
机构
[1] NATL TSING HUA UNIV,INST NUCL SCI,HSINCHU 30043,TAIWAN
关键词
BORON; ELECTROTHERMAL VAPORIZATION INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY MANNITOL CHEMICAL MODIFIER;
D O I
10.1039/ja9951000955
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The possibility of improving the detection sensitivity for boron with the use of mannitol as a chemical modifier in electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) is presented. Experiments were performed by adding mannitol to a boron analyte solution to form a boron-mannitol complex and then injecting the resulting product into the ETV-ICP-MS system for determination, The effect of mannitol on the signal pulse of boron was investigated by monitoring the analyte through a heating cycle from 150 to 2600 degrees C, The appearance of several marked signal pulses at temperatures between 425 and 1500 degrees C was observed and assumed to result from the vaporization of boron-mannitol complexes. The signal intensity of boron in the presence of mannitol was found to be considerably enhanced in comparison with that in its absence, The optimization of the ETV and ICP parameters and the amount of mannitol added and the comparison of mannitol with different modifier systems mere subsequently investigated. It was found that by following the established method the sensitivity for boron in the presence of mannitol can be improved by a factor of 84 compared with that without the modifier, and the limits of detection (3 s) achieved in the presence of mannitol can be as low as 0.2 ng ml(-1) with a 20 mu l injection. The large boron sensitivity enhancement in the presence of mannitol in ETV-ICP-MS is attributed to the formation of a boron-mannitol complex that is subsequently vaporized from the graphite surface and transported with the assistance of mannitol to the plasma. A novel application with mannitol, which acts both as a preconcentrating agent for boron in the chemical separation process and as a modifier in the ETV-ICP-MS for the determination of boron in trichlorosilane, is also presented.
引用
收藏
页码:955 / 961
页数:7
相关论文
共 28 条
[2]  
BARBIER Y, 1968, B SOC CHIM FR, V12, P5072
[3]  
BARNETT N W, 1988, Analytical Proceedings, V25, P233
[4]   MECHANISM OF VOLATILIZATION OF TUNGSTEN IN THE GRAPHITE-FURNACE INVESTIGATED BY ELECTROTHERMAL VAPORIZATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
BYRNE, JP ;
HUGHES, DM ;
CHAKRABARTI, CL ;
GREGOIRE, DC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (09) :913-917
[5]   VAPORIZATION AND ATOMIZATION OF BORON IN THE GRAPHITE-FURNACE INVESTIGATED BY ELECTROTHERMAL VAPORIZATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
BYRNE, JP ;
GREGOIRE, DC ;
GOLTZ, DM ;
CHAKRABARTI, CL .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1994, 49 (05) :433-443
[6]   ELECTROTHERMAL VAPORIZATION FOR SAMPLE INTRODUCTION IN PLASMA SOURCE SPECTROMETRY [J].
CAREY, JM ;
CARUSO, JA .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1992, 23 (05) :397-439
[7]   SPECTROPHOTOMETRIC DETERMINATION OF TRACE AND ULTRATRACE LEVELS OF BORON IN SILICON AND CHLOROSILANE SAMPLES [J].
CHEN, JS ;
LIN, HM ;
YANG, MH .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 340 (06) :357-362
[8]   DETERMINATION OF TRACE IMPURITIES IN SILICON AND CHLOROSILANES BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY AND NEUTRON-ACTIVATION ANALYSIS [J].
CHU, CC ;
CHEN, PY ;
YANG, MH ;
ALFASSI, ZB .
ANALYST, 1990, 115 (01) :29-34
[9]   EQUILIBRIA BETWEEN BORATE ION AND SOME POLYOLS IN AQUEOUS SOLUTION [J].
CONNER, JM ;
BULGRIN, VC .
JOURNAL OF INORGANIC & NUCLEAR CHEMISTRY, 1967, 29 (08) :1953-&
[10]   POTENTIOMETRIC AND POLARIMETRIC STUDIES OF THE REACTION OF BORIC-ACID AND TETRAHYDROXYBORATE ION WITH POLYHYDROXY COMPOUNDS [J].
DAWBER, JG ;
MATUSIN, DH .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1982, 78 :2521-2528