ROLE OF EQUALIZATION MAMMOGRAPHY OF DENSE BREASTS

被引:10
作者
PLEWES, DB [1 ]
SABOL, JM [1 ]
SOUTAR, I [1 ]
CHEVRIER, A [1 ]
SHUMAK, R [1 ]
机构
[1] UNIV TORONTO,SUNNYBROOK HLTH SCI CTR,DEPT RADIOL,TORONTO,ON M4N 2M5,CANADA
关键词
DENSE BREASTS; EQUALIZATION; MAMMOGRAPHY;
D O I
10.1007/BF02523036
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Parenchymal patterns characteristic of dense breasts are known to degrade the mammographic detection of small breast cancers and microcalcifications. This arises from large variations in exposure of the film, resulting in reduced image contrast over areas of suboptimal exposure. Based on sensitometric measurements of mammograms from a typical patient population, it is shown that over 60% of a typical mammogram in Wolfe's DY classification was found to be exposed suboptimally, suggesting a significant margin for improving mammography for these patients. In order to address this problem, a prototype mammographic version of scanning equalisation radiography (MSER) has been developed, which delivers a patient-specific spatially non-uniform distribution of breast exposure, adjusted to maintain optimal film exposure and contrast over the entire mammogram. Anthropomorphic phantom MSER images show a marked improvement in subjective image quality relative to conventional mammograms, while exhibiting a similar radiation risk. The detection of small microcalcifications and fibrils over clinically significant breast densities is found to be improved by factors eight and four, respectively. Such a system may be clinically practical through the use of multiple-beam equalisation methods with available X-ray tube technology.
引用
收藏
页码:167 / 173
页数:7
相关论文
共 30 条
[1]   MAMMOGRAPHIC FEATURES OF THE BREAST AND BREAST-CANCER RISK [J].
BRISSON, J ;
MERLETTI, F ;
SADOWSKY, NL ;
TWADDLE, JA ;
MORRISON, AS ;
COLE, P .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1982, 115 (03) :428-437
[2]   DEVELOPMENT OF AN ANTHROPOMORPHIC BREAST PHANTOM [J].
CALDWELL, CB ;
YAFFE, MJ .
MEDICAL PHYSICS, 1990, 17 (02) :273-280
[3]   CALCULATION OF DOSE AND CONTRAST FOR 2 MAMMOGRAPHIC GRIDS [J].
DANCE, DR ;
PERSLIDEN, J ;
CARLSSON, GA .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01) :235-248
[4]  
EGAN RL, 1977, CANCER, V40, P2087, DOI 10.1002/1097-0142(197711)40:5<2087::AID-CNCR2820400516>3.0.CO
[5]  
2-3
[6]  
GOLD RH, 1979, REDUCED DOSE MAMMOGR, P445
[7]  
GRAVELLE II, 1986, BRIT J RADIOL, V58, P487
[8]   X-RAY CHARACTERIZATION OF NORMAL AND NEOPLASTIC BREAST TISSUES [J].
JOHNS, PC ;
YAFFE, MJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (06) :675-695
[9]   ADVANCED MULTIPLE-BEAM EQUALIZATION RADIOGRAPHY IN CHEST RADIOLOGY - A SIMULATED NODULE DETECTION STUDY [J].
KOOL, LJS ;
BUSSCHER, DLT ;
VLASBLOEM, H ;
HERMANS, J ;
VANDERMERWE, PC ;
ALGRA, PR ;
HERSTEL, W .
RADIOLOGY, 1988, 169 (01) :35-39
[10]   CASE-CONTROL STUDY OF FACTORS ASSOCIATED WITH FAILURE TO DETECT BREAST-CANCER BY MAMMOGRAPHY [J].
MA, L ;
FISHELL, E ;
WRIGHT, B ;
HANNA, W ;
ALLAN, S ;
BOYD, NF .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1992, 84 (10) :781-785