学术探索
学术期刊
新闻热点
数据分析
智能评审
立即登录
GPC - USE OF AUTOMATIC WEIGHING TO DETERMINE ELUTION VOLUMES
被引:5
作者
:
MOEBUS, GA
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV CONNECTICUT,DEPT CHEM,STORRS,CT 06268
UNIV CONNECTICUT,DEPT CHEM,STORRS,CT 06268
MOEBUS, GA
[
1
]
CROWTHER, JA
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV CONNECTICUT,DEPT CHEM,STORRS,CT 06268
UNIV CONNECTICUT,DEPT CHEM,STORRS,CT 06268
CROWTHER, JA
[
1
]
BARTICK, EG
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV CONNECTICUT,DEPT CHEM,STORRS,CT 06268
UNIV CONNECTICUT,DEPT CHEM,STORRS,CT 06268
BARTICK, EG
[
1
]
JOHNSON, JF
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV CONNECTICUT,DEPT CHEM,STORRS,CT 06268
UNIV CONNECTICUT,DEPT CHEM,STORRS,CT 06268
JOHNSON, JF
[
1
]
机构
:
[1]
UNIV CONNECTICUT,DEPT CHEM,STORRS,CT 06268
来源
:
JOURNAL OF APPLIED POLYMER SCIENCE
|
1979年
/ 23卷
/ 12期
关键词
:
D O I
:
10.1002/app.1979.070231206
中图分类号
:
O63 [高分子化学(高聚物)];
学科分类号
:
070305 ;
080501 ;
081704 ;
摘要
:
An automatic balance has been designed, constructed, and tested for continuous determination of the weight of the eluent in chromatography. This balance is considerably more precise than the frequently used automatic siphons. As the elution volume for any molecular species is independent of flow rate over a considerable range, the balance can be used with relatively inexpensive pumps, and thus highly precise constant volume pumps are not required. Copyright © 1979 John Wiley & Sons, Inc.
引用
收藏
页码:3501 / 3504
页数:4
相关论文
共 6 条
[1]
ERRORS CAUSED BY FLOWRATE VARIATION IN HIGH-PERFORMANCE SIZE EXCLUSION CHROMATOGRAPHY (GPC)
BLY, DD
论文数:
0
引用数:
0
h-index:
0
机构:
DUPONT,CENT RES & DEV DEPT,EXPTL STN,WILMINGTON,DE 19898
DUPONT,CENT RES & DEV DEPT,EXPTL STN,WILMINGTON,DE 19898
BLY, DD
STOKLOSA, HJ
论文数:
0
引用数:
0
h-index:
0
机构:
DUPONT,CENT RES & DEV DEPT,EXPTL STN,WILMINGTON,DE 19898
DUPONT,CENT RES & DEV DEPT,EXPTL STN,WILMINGTON,DE 19898
STOKLOSA, HJ
KIRKLAND, JJ
论文数:
0
引用数:
0
h-index:
0
机构:
DUPONT,CENT RES & DEV DEPT,EXPTL STN,WILMINGTON,DE 19898
DUPONT,CENT RES & DEV DEPT,EXPTL STN,WILMINGTON,DE 19898
KIRKLAND, JJ
YAU, WW
论文数:
0
引用数:
0
h-index:
0
机构:
DUPONT,CENT RES & DEV DEPT,EXPTL STN,WILMINGTON,DE 19898
DUPONT,CENT RES & DEV DEPT,EXPTL STN,WILMINGTON,DE 19898
YAU, WW
[J].
ANALYTICAL CHEMISTRY,
1975,
47
(11)
: 1810
-
1813
[2]
SIPHON-COUNTER TECHNIQUE FOR MINIMIZING MOLECULAR-WEIGHT ERRORS CAUSED BY FLOW-RATE VARIATION IN HIGH-PERFORMANCE LIQUID EXCLUSION CHROMATOGRAPHY
BLY, DD
论文数:
0
引用数:
0
h-index:
0
机构:
EI DUPONT DE NEMOURS & CO CENT RES & DEV DEPT,WILMINGTON,DE 19898
EI DUPONT DE NEMOURS & CO CENT RES & DEV DEPT,WILMINGTON,DE 19898
BLY, DD
YAU, WW
论文数:
0
引用数:
0
h-index:
0
机构:
EI DUPONT DE NEMOURS & CO CENT RES & DEV DEPT,WILMINGTON,DE 19898
EI DUPONT DE NEMOURS & CO CENT RES & DEV DEPT,WILMINGTON,DE 19898
YAU, WW
STOKLOSA, HJ
论文数:
0
引用数:
0
h-index:
0
机构:
EI DUPONT DE NEMOURS & CO CENT RES & DEV DEPT,WILMINGTON,DE 19898
EI DUPONT DE NEMOURS & CO CENT RES & DEV DEPT,WILMINGTON,DE 19898
STOKLOSA, HJ
[J].
ANALYTICAL CHEMISTRY,
1976,
48
(08)
: 1256
-
1257
[3]
GEL-PERMEATION CHROMATOGRAPHY - DIFFERENTIAL OPERATION
CHUANG, JY
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV CONNECTICUT,DEPT CHEM & INST MAT SCI,STORRS,CT 06268
UNIV CONNECTICUT,DEPT CHEM & INST MAT SCI,STORRS,CT 06268
CHUANG, JY
JOHNSON, JF
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV CONNECTICUT,DEPT CHEM & INST MAT SCI,STORRS,CT 06268
UNIV CONNECTICUT,DEPT CHEM & INST MAT SCI,STORRS,CT 06268
JOHNSON, JF
[J].
JOURNAL OF APPLIED POLYMER SCIENCE,
1973,
17
(07)
: 2123
-
2129
[4]
ELECTRONIC LABORATORY BALANCES
LEONARD, RO
论文数:
0
引用数:
0
h-index:
0
机构:
PERKIN ELMER CORP,NORWALK,CT 06856
PERKIN ELMER CORP,NORWALK,CT 06856
LEONARD, RO
[J].
ANALYTICAL CHEMISTRY,
1976,
48
(11)
: A879
-
&
[5]
APPLICATION OF AN OLIGOMER AS AN INTERNAL STANDARD IN GEL-PERMEATION CHROMATOGRAPHY
PATEL, GN
论文数:
0
引用数:
0
h-index:
0
机构:
HH WILLS PHYS LAB,BRISTOL BS8 1TL,ENGLAND
HH WILLS PHYS LAB,BRISTOL BS8 1TL,ENGLAND
PATEL, GN
[J].
JOURNAL OF APPLIED POLYMER SCIENCE,
1974,
18
(12)
: 3537
-
3542
[6]
WOLKOFF AW, 1974, J CHROMATOGR SCI, V14, P51
←
1
→
共 6 条
[1]
ERRORS CAUSED BY FLOWRATE VARIATION IN HIGH-PERFORMANCE SIZE EXCLUSION CHROMATOGRAPHY (GPC)
BLY, DD
论文数:
0
引用数:
0
h-index:
0
机构:
DUPONT,CENT RES & DEV DEPT,EXPTL STN,WILMINGTON,DE 19898
DUPONT,CENT RES & DEV DEPT,EXPTL STN,WILMINGTON,DE 19898
BLY, DD
STOKLOSA, HJ
论文数:
0
引用数:
0
h-index:
0
机构:
DUPONT,CENT RES & DEV DEPT,EXPTL STN,WILMINGTON,DE 19898
DUPONT,CENT RES & DEV DEPT,EXPTL STN,WILMINGTON,DE 19898
STOKLOSA, HJ
KIRKLAND, JJ
论文数:
0
引用数:
0
h-index:
0
机构:
DUPONT,CENT RES & DEV DEPT,EXPTL STN,WILMINGTON,DE 19898
DUPONT,CENT RES & DEV DEPT,EXPTL STN,WILMINGTON,DE 19898
KIRKLAND, JJ
YAU, WW
论文数:
0
引用数:
0
h-index:
0
机构:
DUPONT,CENT RES & DEV DEPT,EXPTL STN,WILMINGTON,DE 19898
DUPONT,CENT RES & DEV DEPT,EXPTL STN,WILMINGTON,DE 19898
YAU, WW
[J].
ANALYTICAL CHEMISTRY,
1975,
47
(11)
: 1810
-
1813
[2]
SIPHON-COUNTER TECHNIQUE FOR MINIMIZING MOLECULAR-WEIGHT ERRORS CAUSED BY FLOW-RATE VARIATION IN HIGH-PERFORMANCE LIQUID EXCLUSION CHROMATOGRAPHY
BLY, DD
论文数:
0
引用数:
0
h-index:
0
机构:
EI DUPONT DE NEMOURS & CO CENT RES & DEV DEPT,WILMINGTON,DE 19898
EI DUPONT DE NEMOURS & CO CENT RES & DEV DEPT,WILMINGTON,DE 19898
BLY, DD
YAU, WW
论文数:
0
引用数:
0
h-index:
0
机构:
EI DUPONT DE NEMOURS & CO CENT RES & DEV DEPT,WILMINGTON,DE 19898
EI DUPONT DE NEMOURS & CO CENT RES & DEV DEPT,WILMINGTON,DE 19898
YAU, WW
STOKLOSA, HJ
论文数:
0
引用数:
0
h-index:
0
机构:
EI DUPONT DE NEMOURS & CO CENT RES & DEV DEPT,WILMINGTON,DE 19898
EI DUPONT DE NEMOURS & CO CENT RES & DEV DEPT,WILMINGTON,DE 19898
STOKLOSA, HJ
[J].
ANALYTICAL CHEMISTRY,
1976,
48
(08)
: 1256
-
1257
[3]
GEL-PERMEATION CHROMATOGRAPHY - DIFFERENTIAL OPERATION
CHUANG, JY
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV CONNECTICUT,DEPT CHEM & INST MAT SCI,STORRS,CT 06268
UNIV CONNECTICUT,DEPT CHEM & INST MAT SCI,STORRS,CT 06268
CHUANG, JY
JOHNSON, JF
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV CONNECTICUT,DEPT CHEM & INST MAT SCI,STORRS,CT 06268
UNIV CONNECTICUT,DEPT CHEM & INST MAT SCI,STORRS,CT 06268
JOHNSON, JF
[J].
JOURNAL OF APPLIED POLYMER SCIENCE,
1973,
17
(07)
: 2123
-
2129
[4]
ELECTRONIC LABORATORY BALANCES
LEONARD, RO
论文数:
0
引用数:
0
h-index:
0
机构:
PERKIN ELMER CORP,NORWALK,CT 06856
PERKIN ELMER CORP,NORWALK,CT 06856
LEONARD, RO
[J].
ANALYTICAL CHEMISTRY,
1976,
48
(11)
: A879
-
&
[5]
APPLICATION OF AN OLIGOMER AS AN INTERNAL STANDARD IN GEL-PERMEATION CHROMATOGRAPHY
PATEL, GN
论文数:
0
引用数:
0
h-index:
0
机构:
HH WILLS PHYS LAB,BRISTOL BS8 1TL,ENGLAND
HH WILLS PHYS LAB,BRISTOL BS8 1TL,ENGLAND
PATEL, GN
[J].
JOURNAL OF APPLIED POLYMER SCIENCE,
1974,
18
(12)
: 3537
-
3542
[6]
WOLKOFF AW, 1974, J CHROMATOGR SCI, V14, P51
←
1
→