INVITRO AND INVIVO EVALUATION OF INTRALUMINAL ULTRASOUND IN NORMAL AND ATHEROSCLEROTIC ARTERIES

被引:25
作者
TABBARA, M [1 ]
KOPCHOK, G [1 ]
WHITE, RA [1 ]
机构
[1] UNIV CALIF LOS ANGELES,LOS ANGELES CTY HARBOR MED CTR,DEPT SURG,1000 W CARSON ST,TORRANCE,CA 90509
关键词
D O I
10.1016/S0002-9610(05)80745-7
中图分类号
R61 [外科手术学];
学科分类号
摘要
This study evaluated the dimensional and morphologic precision of arterial images obtained using intraluminal rotating A-scan ultrasound catheters [5.0F (30 mHz) and 8.0F (20 mHz)]. Dimensions of in vitro ultrasound images from human arteries (eight normal and nine arteriosclerotic) were compared with those from histologic sections of the vessels. In addition, in vivo ultrasound studies (23 normal and 22 arteriosclerotic) of canine femoral arteries were compared with luminal dimensions obtained from angiograms of the vessels. The correlation of in vitro ultrasound images to luminal diameters (n=22, r=0.96), adventitial diameters (n=19, r=0.83), and wall thickness (n=19, r=0.68) in normal human vessels was significant (p<0.05). In vitro measurements of images and histologic specimens from human atherosclerotic arteries also correlated significantly (p<0.05) with luminal diameters (n=27, r=0.91), adventitial diameters (n=24, r=0.60), and wall thickness (n=24, r=0.62). Morphologically, in vitro images of the wall of normal human arteries had a concentric laminated appearance and atherosclerotic vessels had patchy echodense and echolucent areas. In vivo studies showed significant correlation of diameters for both normal (n=16, r=0.91, p<0.05) and arteriosclerotic (n=16, r=0.57, p<0.05) canine arteries compared with luminal dimensions measured from uniplanar angiograms. We conclude that rotating A-scan intraluminal ultrasound accurately defines both normal and atherosclerotic arterial wall morphology and dimensions. This technology may be valuable for intravascular guidance of angioplasty devices by identifying the location and consistency of lesions. © 1990 Reed Publishing USA.
引用
收藏
页码:556 / 560
页数:5
相关论文
共 13 条
[1]  
BOND MG, 1981, ARTERY, V9, P21
[2]  
Fujitani R M, 1988, J Invest Surg, V1, P277, DOI 10.3109/08941938809141093
[3]  
GRAHAM S P, 1989, Journal of the American College of Cardiology, V13, p222A
[4]  
HODGSON J, 1988, CIRCULATION S2, V78, P21
[5]  
KOPCHOK G, IN PRESS VASCULAR SU
[6]   FEASIBILITY OF HIGH-RESOLUTION, INTRAVASCULAR ULTRASONIC-IMAGING CATHETERS [J].
MEYER, CR ;
CHIANG, EH ;
FECHNER, KP ;
FITTING, DW ;
WILLIAMS, DM ;
BUDA, AJ .
RADIOLOGY, 1988, 168 (01) :113-116
[7]   ULTRASOUND ANGIOSCOPY - REAL-TIME, TWO-DIMENSIONAL, INTRALUMINAL ULTRASOUND IMAGING OF BLOOD-VESSELS [J].
PANDIAN, NG ;
KREIS, A ;
BROCKWAY, B ;
ISNER, JM ;
SACHAROFF, A ;
BOLEZA, E ;
CARO, R ;
MULLER, D .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (07) :493-494
[8]   INTIMAL PLUS MEDIAL THICKNESS OF THE ARTERIAL-WALL - A DIRECT MEASUREMENT WITH ULTRASOUND IMAGING [J].
PIGNOLI, P ;
TREMOLI, E ;
POLI, A ;
ORESTE, P ;
PAOLETTI, R .
CIRCULATION, 1986, 74 (06) :1399-1406
[9]  
Roberts W C, 1975, Pathobiol Annu, V5, P249
[10]  
SUMNER DS, 1983, CEREBROVASCULAR INSU, P115