PROSPECTIVE COMPARISON OF THE EFFECTS OF OCCUCOAT, VISCOAT, AND HEALON ON INTRAOCULAR-PRESSURE AND ENDOTHELIAL-CELL LOSS

被引:56
作者
LANE, SS
NAYLOR, DW
KULLERSTRAND, LJ
KNAUTH, K
LINDSTROM, RL
机构
[1] Ophthalmology Section, Veteran's Affairs Medical Center, Minneapolis, Minnesota
关键词
ENDOTHELIAL CELL LOSS; EXTRACAPSULAR CATARACT EXTRACTION; HYDROXYPROPYLMETHYLCELLULOSE; INTRAOCULAR PRESSURE; POSTERIOR CHAMBER LENS IMPLANTATION; SODIUM HYALURONATE; SODIUM HYALURONATE-CHONDROITIN SULFATE; SPECULAR MICROSCOPY;
D O I
10.1016/S0886-3350(13)80979-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We compared the effect of Occucoat (2% hydroxypropylmethylcellulose), Viscoat (sodium hyaluronate-chondroitin sulfate), and Healon (sodium hyaluronate) on postoperative intraocular pressure (IOP) and endothelial cell damage. One hundred fourteen patients having planned extracapsular cataract extraction with posterior chamber lens implantation using a viscomaterial were prospectively randomized into one of five groups. Group I received Occucoat which was removed from the anterior chamber at the conclusion of surgery. Group II received Occucoat which was not removed (retained). Group III received Viscoat which was removed, Group IV received Viscoat which was retained, and Group V received Healon which was removed. No prophylactic ocular hypotensive medications were given. Intraocular pressure was measured at four hours, 24 hours, one week, one month, three months, and one year postoperatively. Compared to preoperative IOP, all groups had a significant IOP increase at four hours. All but the Viscoat removed group (Group III) showed a statistically significant increase at 24 hours postoperatively (P < .05). No group had a significant increase at one week or later. Specular microscopy showed no significant difference in cell loss between any of the groups at three months or within each group when compared to preoperative cell counts (P > .1).
引用
收藏
页码:21 / 26
页数:6
相关论文
共 35 条
[1]  
Crane EL, Polack FM, Balazs EA., The protective effect of Na-hyaluronate to corneal endothelium, Exp Eye Res, 31, pp. 119-127, (1980)
[2]  
Pape LG, Balazs EA., The use of sodium hyaluronate (Healon®) in human anterior segment surgery, Ophthalmology, 87, pp. 699-705, (1980)
[3]  
Hoopes PC., Sodium hyaluronate (Healon®) in anterior segment surgery: A review and a new use in extracapsular surgery, Am Intra-Ocular Implant Soc J, 8, pp. 148-154, (1982)
[4]  
Barron BA, Busin M, Page C, Et al., Comparison of the effects of Viscoat and Healon on postoperative intraocular pressure, Am J Ophthalmol, 100, pp. 377-384, (1985)
[5]  
Pape LG., Intracapsular and extracapsular technique of lens implantation with Healon®, Am Intra-Ocular Implant Soc J, 6, pp. 342-343, (1980)
[6]  
Hoffer KJ., Effects of extracapsular implant techniques on endothelial density, Arch Ophthalmol, 100, pp. 791-792, (1982)
[7]  
Cherfan GM, Rich WJ, Wright G., Raised intraocular pressure and other problems with sodium hyaluronate and cataract surgery, Trans Ophthalmol Soc UK, 103, pp. 277-279, (1983)
[8]  
Glasser DB, Matsuda M, Edelhauser HEA, comparison of the efficacy and toxicity of and intraocular pressure response to viscous solutions in the anterior chamber, Arch Ophthalmol, 104, pp. 1819-1824, (1986)
[9]  
Mac Rae SM, Edelhauser HE Hyndiuk RA, Et al., The effects of sodium hyaluronate, chondroitin sulfate, and methylcellulose on the corneal endothelium and intraocular pressure, Am J Ophthalmol, 95, pp. 332-341, (1983)
[10]  
Thomsen M, Simonsen AH, Andreassen TT., Comparison of sodium hyaluronate and methylcellulose in extracapsular cataract extraction, Acta Ophthalmol, 65, pp. 400-405, (1987)