MAGNETIC-RESONANCE-IMAGING DETECTION OF AN EXPERIMENTAL PULMONARY PERFUSION DEFICIT USING A MACROMOLECULAR CONTRAST AGENT - POLYLYSINE-GADOLINIUM-DTPA(40)

被引:50
作者
BERTHEZENE, Y
VEXLER, V
PRICE, DC
WISNERDUPON, J
MOSELEY, ME
AICHER, KP
BRASCH, RC
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT RADIOL,CONTRAST MED LAB,513 PARNASSUS AVE,SAN FRANCISCO,CA 94143
[2] UNIV CALIF SAN FRANCISCO,DEPT RADIOL,NUCL MED SECT,SAN FRANCISCO,CA 94143
关键词
CONTRAST AGENTS; CONTRAST-ENHANCED MAGNETIC RESONANCE IMAGING; MACROMOLECULAR MAGNETIC RESONANCE IMAGING; PULMONARY EMBOLISM;
D O I
10.1097/00004424-199205000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. This study was designed to evaluate the potential of a blood-pool magnetic resonance (MR) contrast agent, polylysine-gadolinium-DTPA40 (polylysine-Gd-DTPA40) for detecting pulmonary perfusion defects. MATERIALS AND METHODS. Pulmonary emboli were induced in 10 rats by venous injection of 0.2 mL of air. Axial spin-echo images were acquired (TR = 800 mseconds; TE = 6 mseconds) before and after air injection and serially after the administration of polylysine-Gd-DTPA40. The embolism model was confirmed by scintigraphy using Tc-99m-macroaggregated albumin. RESULTS. Signal intensity differences between normal and embolized lungs before and after the air injection were less than 25%. After polylysine-Gd-DTPA40 administration, signal intensity of the perfused lung increased more than 200%, whereas the embolized lung increased by only 25%. Signal intensities of the perfused lung remained stable for 1 hour, whereas signal intensities of the embolized lung gradually increased for 20 minutes as the air embolus dissolved. CONCLUSION. Magnetic resonance imaging (MRI) enhanced with a macromolecular blood-pool contrast agent can be used to detect acute pulmonary embolism in a confirmed animal model.
引用
收藏
页码:346 / 351
页数:6
相关论文
共 14 条
  • [1] LUNG PARENCHYMA - MAGNETIC-SUSCEPTIBILITY IN MR IMAGING
    BERGIN, CJ
    GLOVER, GH
    PAULY, JM
    [J]. RADIOLOGY, 1991, 180 (03) : 845 - 848
  • [2] LUNG PARENCHYMA - PROJECTION RECONSTRUCTION MR-IMAGING
    BERGIN, CJ
    PAULY, JM
    MACOVSKI, A
    [J]. RADIOLOGY, 1991, 179 (03) : 777 - 781
  • [3] VENTILATION-PERFUSION STUDIES IN SUSPECTED PULMONARY-EMBOLISM
    BIELLO, DR
    MATTAR, AG
    MCKNIGHT, RC
    SIEGEL, BA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1979, 133 (06) : 1033 - 1037
  • [4] CONTRAST-ENHANCED NMR IMAGING - ANIMAL STUDIES USING GADOLINIUM-DTPA COMPLEX
    BRASCH, RC
    WEINMANN, HJ
    WESBEY, GE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 142 (03) : 625 - 630
  • [5] BUCHANANDAVIDSON DJ, 1959, J IMMUNOL, V83, P552
  • [6] PULMONARY VASCULAR CINE MR IMAGING - A NONINVASIVE APPROACH TO DYNAMIC IMAGING OF THE PULMONARY CIRCULATION
    GEFTER, WB
    HATABU, H
    DINSMORE, BJ
    AXEL, L
    PALEVSKY, HI
    REICHEK, N
    SCHIEBLER, ML
    KRESSEL, HY
    [J]. RADIOLOGY, 1990, 176 (03) : 761 - 770
  • [7] MARCHAL G J, 1990, Magnetic Resonance Imaging, V8, P88
  • [8] MAUER P, 1959, J IMMUNOL, V83, P193
  • [9] SUBGROSS PULMONARY ANATOMY IN ARIOUS MAMMALS AND MAN
    MCLAUGHLIN, R
    CANADA, RO
    TYLER, WS
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1961, 175 (08): : 694 - &
  • [10] CINE GRADIENT-REFOCUSED MR IMAGING OF CENTRAL PULMONARY EMBOLI
    POSTERARO, RH
    SOSTMAN, HD
    SPRITZER, CE
    HERFKENS, RJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (03) : 465 - 468