DETERMINATION OF BOTH MECHANICAL AND ELECTRONIC SHIFTS IN CONE-BEAM SPECT

被引:50
作者
LI, JY
JASZCZAK, RJ
WANG, HL
GREER, KL
COLEMAN, RE
机构
[1] Dept. of Radiol., Duke Univ., Med. Center, Durham, NC
关键词
D O I
10.1088/0031-9155/38/6/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The difference between the displacement of the centre of rotation (mechanical shift, ms) and the electronic centring misalignment (electronic shift, ES) in cone beam SPECT is evaluated. A method is proposed to determine both ms and ES using the centroid of a projected point source sampled over 360-degrees and the Marquardt non-linear fitting algorithm. Both shifts are characterized by two orthogonal components. This method is verified using Monte Carlo simulated point source data with different combinations of mechanical and electronic shifts. Both shifts can be determined correctly. We have also applied the proposed method to our cone beam SPECT system to determine both shifts as well as the focal length. The determined ES parameters are then used to correct the projections and the ms parameters are incorporated into a reconstruction algorithm. The point source images are reconstructed and the image resolutions with and without the shift corrections are measured. The experimental results demonstrate that the image resolution is improved after shift corrections. The experimental results also indicate that the shift parameters determined in the same experiment with the point source located at different places are consistent but change from time to time, suggesting that calibration of the system is needed on a periodic basis.
引用
收藏
页码:743 / 754
页数:12
相关论文
共 30 条
  • [1] BELLINI S, 1979, IEEE T ACOUSTICS SPE, V2, P2131
  • [2] 3-DIMENSIONAL RECONSTRUCTION IN NUCLEAR-MEDICINE EMISSION IMAGING
    BUDINGER, TF
    GULLBERG, GT
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (03) : 2 - 20
  • [4] FLOYD CE, 1986, J NUCL MED, V27, P1577
  • [5] GRANGEAT P, 1991, EVALUATION 3D RADON, V1445, P320
  • [6] GREEN AJ, 1988, EUR J NUCL MED, V14, P226
  • [7] ESTIMATION OF GEOMETRICAL PARAMETERS FOR FAN BEAM TOMOGRAPHY
    GULLBERG, GT
    TSUI, BMW
    CRAWFORD, CR
    EDGERTON, ER
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (12) : 1581 - 1594
  • [8] ESTIMATION OF GEOMETRICAL PARAMETERS AND COLLIMATOR EVALUATION FOR CONE BEAM TOMOGRAPHY
    GULLBERG, GT
    TSUI, BMW
    CRAWFORD, CR
    BALLARD, JG
    HAGIUS, JT
    [J]. MEDICAL PHYSICS, 1990, 17 (02) : 264 - 272
  • [9] AN ATTENUATED PROJECTOR BACKPROJECTOR FOR ITERATIVE SPECT RECONSTRUCTION
    GULLBERG, GT
    HUESMAN, RH
    MALKO, JA
    PELC, NJ
    BUDINGER, TF
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (08) : 799 - 816
  • [10] CONE BEAM TOMOGRAPHY OF THE HEART USING SINGLE-PHOTON EMISSION-COMPUTED TOMOGRAPHY
    GULLBERG, GT
    CHRISTIAN, PE
    ZENG, GSL
    DATZ, FL
    MORGAN, HT
    [J]. INVESTIGATIVE RADIOLOGY, 1991, 26 (07) : 681 - 688