DIRECT IN-VIVO VISUALIZATION OF RIGHT CARDIAC ANATOMY BY FIBEROPTIC ENDOSCOPY - HEMODYNAMIC-EFFECTS AND IMAGE VALIDATION

被引:1
作者
FUJIMURA, O [1 ]
LAWTON, MA [1 ]
KOCH, CA [1 ]
机构
[1] UNIV KENTUCKY,MED CTR,DEPT MED,DIV CARDIOL,SER ARRHYTHMIA,LEXINGTON,KY 40536
关键词
D O I
10.1177/000331979504600303
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The authors tested the ability of a balloon-tipped fiberoptic endoscope to accurately visualize and identify right-heart anatomy in 7 anesthetized dogs. A 3.6-mm-diameter fiberoptic endoscope with a latex balloon covering the distal tip was inserted into the right atrium, where the balloon was inflated with air in 5 mL increments. Heart rate did not show changes. Mean arterial pressure and cardiac output started to show significant decreases with a balloon volume at 25 and 20 mL, respectively (n = 7). Visual image quality was excellent with a balloon volume of 10 mL or greater. With a balloon volume of 7-10 mL, the visual field was 15-20 mm in diameter. Right-heart anatomy including the right free wall, ostium of the coronary sinus, atrioventricular node area, tricuspid valve, right ventricular structures, and pulmonary arteries was clearly and accurately identified. Additionally, spatial relationships among these structures could be established. Furthermore, there was an excellent concordance between endoscopically observed images and postmortem findings. In conclusion, balloon-tipped fiberoptic endoscopy can accurately visualize normal intracardiac structures with no or minimal hemodynamic compromise.
引用
收藏
页码:201 / 209
页数:9
相关论文
共 8 条
[1]  
DEE P, 1979, BRIT HEART J, V39, P459
[2]   CORONARY ANGIOSCOPY IN PATIENTS WITH UNSTABLE ANGINA-PECTORIS [J].
SHERMAN, CT ;
LITVACK, F ;
GRUNDFEST, W ;
LEE, M ;
HICKEY, A ;
CHAUX, A ;
KASS, R ;
BLANCHE, C ;
MATLOFF, J ;
MORGENSTERN, L ;
GANZ, W ;
SWAN, HJC ;
FORRESTER, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1986, 315 (15) :913-919
[3]   IDENTIFICATION OF PULMONARY EMBOLI IN THE DOG - COMPARISON OF ANGIOSCOPY AND PERFUSION SCANNING [J].
SHURE, D ;
MOSER, KM ;
HARRELL, JH ;
HARTMAN, MT .
CIRCULATION, 1981, 64 (03) :618-621
[4]   HEMODYNAMICS AND GAS-EXCHANGE DURING ANGIOSCOPY IN THE DOG [J].
SHURE, D ;
MOSER, KM ;
KONOPKA, RG .
ANGIOLOGY, 1984, 35 (02) :97-103
[5]  
SHURE D, 1985, SPIE, V576, P32
[6]   INVIVO CORONARY ANGIOSCOPY [J].
SPEARS, JR ;
MARAIS, HJ ;
SERUR, J ;
POMERANTZEFF, O ;
GEYER, RP ;
SIPZENER, RS ;
WEINTRAUB, R ;
THURER, R ;
PAULIN, S ;
GERSTIN, R ;
GROSSMAN, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 1 (05) :1311-1314
[7]  
TANABE T, 1980, SURGERY, V87, P375
[8]   FIBEROPTIC ANGIOSCOPY OF CARDIAC CHAMBERS, VALVES, AND GREAT-VESSELS USING A GUIDING BALLOON CATHETER IN DOGS [J].
UCHIDA, Y ;
TOMARU, T ;
NAKAMURA, F ;
SONOKI, H ;
SUGIMOTO, T .
AMERICAN HEART JOURNAL, 1988, 115 (06) :1297-1302