THE CHIP AND FLIP PHACOEMULSIFICATION TECHNIQUE

被引:33
作者
FINE, IH
机构
关键词
CAPSULORHEXIS; INCREASED SAFETY AND CONTROL; 2-HANDED ENDOLENTICULAR PHACOEMULSIFICATION;
D O I
10.1016/S0886-3350(13)80835-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The "chip and flip" phacoemulsification technique increases safety and control within the capsular bag. The surgical maneuvers use a two-handed technique through a small curvilinear capsulorhexis.
引用
收藏
页码:366 / 371
页数:6
相关论文
共 7 条
[1]  
Neuhann T, Theorie and Operationstechnik der Kapsulorhexis, Klin Monatsbl Augenheilkd, 190, pp. 542-545, (1987)
[2]  
Gimbel HV, Neuhann T, Development, advantages, and methods of the continuous circular capsulorhexis technique, J Cataract Refract Surg, 16, pp. 31-37, (1990)
[3]  
Davison JA, Bimodal capsular bag phacoemulsification: A serial cutting and suction ultrasonic nuclear dissection technique, J Cataract Refract Surg, 15, pp. 272-282, (1989)
[4]  
Shepherd JR, In situ fracture, J Cataract Refract Surg, 16, pp. 436-440, (1990)
[5]  
Davison JA, Hybrid nuclear dissection technique for capsular bag phacoemulsification, J Cataract Refract Surg, 16, pp. 441-450, (1990)
[6]  
Arnold PN, One-handed method of posterior chamber phacoemulsification, J Cataract Refract Surg, 16, pp. 646-648, (1990)
[7]  
Gimbel HV, Divide and conquer nucleofractis phacoemulsification: Development and variations, J Cataract Refract Surg, 17, pp. 281-291, (1991)