COMPARISON OF 2-DIMENSIONAL AND 3-DIMENSIONAL ECHOCARDIOGRAPHY WITH CINEVENTRICULOGRAPHY FOR MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN PATIENTS

被引:100
作者
SAPIN, PM [1 ]
SCHRODER, KM [1 ]
GOPAL, AS [1 ]
SMITH, MD [1 ]
DEMARIA, AN [1 ]
KING, DL [1 ]
机构
[1] COLUMBIA UNIV,COLL PHYS & SURG,NEW YORK,NY
关键词
D O I
10.1016/0735-1097(94)90869-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. We compared two- and three-dimensional echocardiography with cineventriculography for measurement of left ventricular volume in patients. Background. Three-dimensional echocardiography has been shown to be highly accurate and superior to two-dimensional echocardiography in measuring left ventricular volume in vitro. However, there has been little comparison of the two methods in patients. Methods. Two- and three-dimensional echocardiography were performed in 35 patients (mean age 48 years) 1 to 3 h before left ventricular cineventriculography. Three-dimensional echocardiography used an acoustic spatial locator to register image position. Volume was computed using a polyhedral surface reconstruction algorithm based on multiple nonparallel, unevenly spaced short-axis cross sections. Two-dimensional echocardiography used the apical biplane summation of disks method. Single plane cineventriculographic volumes were calculated using the summation of disks algorithm. The methods were compared by linear regression and a limits of agreement analysis. For the latter, systematic error was assessed by the mean of the differences (cineventriculography minus echocardiography), and the limits of agreement were defined as +/-2 SD from the mean difference. Results. Three dimensional echocardiographic volumes demonstrated excellent correlation (end-diastole r = 0.97; end-systole r = 0.98) with cineventriculography. Standard errors of the estimate were approximately half those of two-dimensional echocardiography (end-diastole +/-11.0 ml vs. +/-21.5 ml; end-systole +/-10.2 ml vs. +/-17.0 ml). By limits of agreement analysis the end-diastolic mean differences for two- and three-dimensional echocardiography were 21.1 and 12.9 ml, respectively. The limits of agreement (+/-2 SD) were +/-54.0 and +/-24.8 ml, respectively. For end-systole, comparable improvement was obtained by three-dimensional echocardiography. Results for ejection fraction by the two methods were similar. Conclusions. Three-dimensional echocardiography correlates highly with cineventriculography for estimation of ventricular volumes in patients and has approximately half the variability of two-dimensional echocardiography for these measurements. On the basis of this study, three-dimensional echocardiography is the preferred echocardiographic technique for measurement of ventricular volume. Three-dimensional echocardiography is equivalent to two-dimensional echocardiography for measuring ejection fraction.
引用
收藏
页码:1054 / 1063
页数:10
相关论文
共 31 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]   INVITRO EVALUATION OF AN ULTRASONIC 3-DIMENSIONAL IMAGING AND VOLUME SYSTEM [J].
BRINKLEY, JF ;
MURAMATSU, SK ;
MCCALLUM, WD ;
POPP, RL .
ULTRASONIC IMAGING, 1982, 4 (02) :126-139
[3]   AN ALGORITHM FOR VOLUME ESTIMATION BASED ON POLYHEDRAL APPROXIMATION [J].
COOK, LT ;
COOK, PN ;
LEE, KR ;
BATNITZKY, S ;
WONG, BYS ;
FRITZ, SL ;
OPHIR, J ;
DWYER, SJ ;
BIGONGIARI, LR ;
TEMPLETON, AW .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (09) :493-500
[4]   ECHOVENTRICULOGRAPHY - A SIMULTANEOUS ANALYSIS OF TWO-DIMENSIONAL ECHOCARDIOGRAPHY AND CINEVENTRICULOGRAPHY [J].
ERBEL, R ;
SCHWEIZER, P ;
LAMBERTZ, H ;
HENN, G ;
MEYER, J ;
KREBS, W ;
EFFERT, S .
CIRCULATION, 1983, 67 (01) :205-215
[5]   DYNAMIC 3-DIMENSIONAL ECHOCARDIOGRAPHIC RECONSTRUCTION OF THE INTACT HUMAN LEFT-VENTRICLE - TECHNIQUE AND INITIAL OBSERVATIONS IN PATIENTS [J].
GEISER, EA ;
ARIET, M ;
CONETTA, DA ;
LUPKIEWICZ, SM ;
CHRISTIE, LG ;
CONTI, CR .
AMERICAN HEART JOURNAL, 1982, 103 (06) :1056-1065
[6]   3-DIMENSIONAL RECONSTRUCTION OF ECHOCARDIOGRAPHIC IMAGES USING THE ROTATION METHOD [J].
GHOSH, A ;
NANDA, NC ;
MAURER, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (06) :655-661
[7]  
Gopal A S, 1992, J Am Soc Echocardiogr, V5, P115
[8]   LEFT-VENTRICULAR VOLUME AND ENDOCARDIAL SURFACE-AREA BY 3-DIMENSIONAL ECHOCARDIOGRAPHY - COMPARISON WITH 2-DIMENSIONAL ECHOCARDIOGRAPHY AND NUCLEAR-MAGNETIC-RESONANCE IMAGING IN NORMAL SUBJECTS [J].
GOPAL, AS ;
KELLER, AM ;
RIGLING, R ;
KING, DL ;
KING, DL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (01) :258-270
[9]  
Gorge G, 1992, J Am Soc Echocardiogr, V5, P125
[10]   A NEW INTEGRATED SYSTEM FOR 3-DIMENSIONAL ECHOCARDIOGRAPHIC RECONSTRUCTION - DEVELOPMENT AND VALIDATION FOR VENTRICULAR VOLUME WITH APPLICATION IN HUMAN-SUBJECTS [J].
HANDSCHUMACHER, MD ;
LETHOR, JP ;
SIU, SC ;
MELE, D ;
RIVERA, JM ;
PICARD, MH ;
WEYMAN, AE ;
LEVINE, RA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (03) :743-753