MAXIMAL INSPIRATORY PRESSURE IS NOT A RELIABLE TEST OF INSPIRATORY MUSCLE STRENGTH IN MECHANICALLY VENTILATED PATIENTS

被引:64
作者
MULTZ, AS [1 ]
ALDRICH, TK [1 ]
PREZANT, DJ [1 ]
KARPEL, JP [1 ]
HENDLER, JM [1 ]
机构
[1] MONTEFIORE MED CTR,ALBERT EINSTEIN COLL MED,DEPT MED,DIV PULM,111 E 210TH ST,BRONX,NY 10467
来源
AMERICAN REVIEW OF RESPIRATORY DISEASE | 1990年 / 142卷 / 03期
关键词
D O I
10.1164/ajrccm/142.3.529
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Maximal inspiratory pressure (MIP) is an important clinical method used to assess respiratory muscle strength. The reliability and reproducibility of this measurement in mechanically ventilated patients is not certain. In 14 stable, mechanically ventilated patients, capable of spontaneous inspiratory efforts, we assessed maximal inspiratory efforts using the technique originally described by Marini and associates. MIP was measured in triplicate, by one to five experienced investigators, on one to seven successive days, for a total of 396 determinations on 54 patient days. The coefficients of variation among the triplicate efforts averaged 12 ± 1%, indicating the test to be highly reproducible. There was significant variation among the MIP reported by different investigators studying the same patient on the same day (32 ± 4%). The differences between best MIP by different investigators averaged 12.6 ± 1.3 cm H2O (40 ± 4%). In 17 of 44 cases, one investigator placed MIP above -30 cm H2O, whereas another placed it below. ANOVA showed that MIP was significantly affected by investigator (p < 0.0001) as well as by patient (p < 0.0001). Because 'true' MIP must be equal to or greater than the best measured MIP, these data indicate that the MIP is commonly underestimated in patients receiving mechanical ventilation, even when standardized technique is used. Furthermore, our data show that reproducibility of triplicate MIP determination by a single observer does not indicate that the test is reliable.
引用
收藏
页码:529 / 532
页数:4
相关论文
共 18 条
[1]   ASSESSMENT OF HUMAN DIAPHRAGM STRENGTH AND ACTIVATION USING PHRENIC-NERVE STIMULATION [J].
BELLEMARE, F ;
BIGLANDRITCHIE, B .
RESPIRATION PHYSIOLOGY, 1984, 58 (03) :263-277
[2]  
BLACK LF, 1969, AM REV RESPIR DIS, V99, P696
[3]  
BLACK LF, 1971, AM REV RESPIR DIS, V103, P641
[4]   FORCE-LENGTH RELATIONSHIP OF THE NORMAL HUMAN DIAPHRAGM [J].
BRAUN, NMT ;
ARORA, NS ;
ROCHESTER, DF .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 53 (02) :405-412
[5]  
BYRD RB, 1968, AM REV RESPIR DIS, V98, P848
[6]   EVALUATION OF 2 DIFFERENT EXTUBATION CRITERIA - ATTRIBUTES CONTRIBUTING TO SUCCESS [J].
DEHAVEN, CB ;
HURST, JM ;
BRANSON, RD .
CRITICAL CARE MEDICINE, 1986, 14 (02) :92-94
[7]   ACTIVATION OF THE HUMAN DIAPHRAGM DURING MAXIMAL STATIC EFFORTS [J].
GANDEVIA, SC ;
MCKENZIE, DK .
JOURNAL OF PHYSIOLOGY-LONDON, 1985, 367 (OCT) :45-56
[8]   TOWARDS AN OBJECTIVE ASSESSMENT OF THE MAXIMAL VOLUNTARY CONTRACTION COMPONENT IN ROUTINE MUSCLE STRENGTH MEASUREMENTS [J].
KROEMER, KHE ;
MARRAS, WS .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1980, 45 (01) :1-9
[9]   MECHANISMS DETERMINING RESIDUAL VOLUME OF LUNGS IN NORMAL SUBJECTS [J].
LEITH, DE ;
MEAD, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1967, 23 (02) :221-&
[10]  
MARINI J J, 1986, Journal of Critical Care, V1, P32, DOI 10.1016/S0883-9441(86)80114-9