PULSATILE FLOW ARTIFACTS IN FAST MAGNETIZATION-PREPARED SEQUENCES

被引:2
作者
TASCIYAN, TA
MITCHELL, DG
机构
[1] Department of Radiology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, 19107, Main Bldg, Rm 1080
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1994年 / 4卷 / 02期
关键词
ABDOMEN; ARTIFACT; FLOW SIMULATION; IMAGE PROCESSING; PHASE-ENCODING ORDER; PULSE SEQUENCES; RAPID IMAGING; VASCULAR STUDIES;
D O I
10.1002/jmri.1880040221
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fast magnetization-prepared magnetic resonance imaging sequences allow clinical acquisitions in about 1 second, with the preparation phase providing the desired contrast. Pulsatile flow artifacts, although reduced by rapid acquisition, can degrade image quality. The authors explore the causes of aortic pulsatile flow artifacts in inversion-recovery-prepared acquisitions of the abdomen, taking into consideration various parameters. The flow signal within an 8-mm-thick section was simulated and subsequently Fourier transformed to determine the location and extent of flow artifacts. Results of simulations were validated with abdominal images of human subjects. Recording all encodings within one cardiac cycle reduced pulsatile flow artifacts in nonsegmented acquisitions with sequential phase-encoding order, regardless of the location of magnetization preparation within the cardiac cycle. In segmented acquisitions, however, the sequential order always increased flow artifacts. To reduce the artifacts in short TI acquisitions, the magnetization should be prepared during diastole. In clinical acquisitions, flow artifacts were further reduced by modifying the phase-encoding scheme.
引用
收藏
页码:217 / 222
页数:6
相关论文
共 23 条
[1]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[2]   STRATEGIES TO IMPROVE CONTRAST IN TURBOFLASH IMAGING - REORDERED PHASE ENCODING AND K-SPACE SEGMENTATION [J].
CHIEN, D ;
ATKINSON, DJ ;
EDELMAN, RR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (01) :63-70
[3]  
CHIEN D, 1991, Magnetic Resonance Quarterly, V7, P31
[4]   FRODO PULSE SEQUENCES - A NEW MEANS OF ELIMINATING MOTION, FLOW, AND WRAPAROUND ARTIFACTS [J].
EDELMAN, RR ;
ATKINSON, DJ ;
SILVER, MS ;
LOAIZA, FL ;
WARREN, WS .
RADIOLOGY, 1988, 166 (01) :231-236
[5]   FLOW ARTIFACT REDUCTION IN MRI - A REVIEW OF THE ROLES OF GRADIENT MOMENT NULLING AND SPATIAL PRESATURATION [J].
EHMAN, RL ;
FELMLEE, JP .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :293-307
[6]   SPATIAL PRESATURATION - A METHOD FOR SUPPRESSING FLOW ARTIFACTS AND IMPROVING DEPICTION OF VASCULAR ANATOMY IN MR IMAGING [J].
FELMLEE, JP ;
EHMAN, RL .
RADIOLOGY, 1987, 164 (02) :559-564
[7]   NUCLEAR MAGNETIC-RESONANCE SIGNAL FROM FLOWING NUCLEI IN RAPID IMAGING USING GRADIENT ECHOES [J].
GAO, JH ;
HOLLAND, SK ;
GORE, JC .
MEDICAL PHYSICS, 1988, 15 (06) :809-814
[8]   MECHANISMS OF SIGNAL LOSS IN MAGNETIC-RESONANCE-IMAGING OF STENOSES [J].
GATENBY, JC ;
MCCAULEY, TR ;
GORE, JC .
MEDICAL PHYSICS, 1993, 20 (04) :1049-1057
[9]  
HAACKE E M, 1986, Magnetic Resonance Imaging, V4, P359, DOI 10.1016/0730-725X(86)91046-5
[10]  
Hatle L, 1985, DOPPLER ULTRASOUND C, V2nd