COLORECTAL-CARCINOMA METASTASES - DETECTION WITH IN-111 LABELED MONOCLONAL-ANTIBODY CCR 086

被引:16
作者
ABDELNABI, HH
LEVINE, G
LAMKI, LM
MURRAY, JL
TAUXE, WN
SHAH, AN
PATT, YZ
DOERR, RJ
KLEIN, HA
GONA, J
ROSENBLUM, MJ
UNGER, MJ
SMITH, LM
SCHWEIGHARDT, SA
MERCHANT, EB
机构
[1] SUNY BUFFALO,VET ADM MED CTR,SCH MED & BIOMED SCI,DEPT SURG,BUFFALO,NY 14214
[2] UNIV PITTSBURGH,PRESBYTERIAN HOSP,SCH MED,PITTSBURGH CANC INST,PITTSBURGH,PA 15213
[3] UNIV TEXAS,MD ANDERSON HOSP & TUMOR INST,CTR CANC,HOUSTON,TX 77030
[4] HYBRITECH INC,SAN DIEGO,CA
关键词
Colon; neoplasms; indium; radioactive; liver neoplasms; secondary; liver; radionuclide studies; lung neoplasms; lung; monoclonal antibodies; rectum;
D O I
10.1148/radiology.176.1.2353080
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A phase I/II clinical trial with indium-111-labeled antimucin murine monoclonal antibody (MoAb) CCR 086 was conducted. Seventeen patients with histologically proved colorectal carcinoma and known metastatic disease underwent external scintigraphy after administration of 5.5 mCi (203.5 MBq) of In-111 CCR 086 at doses of 5 and 20 mg. Of 25 known lesions, 17 were detected (sensitivity, 68%). The smallest detected lesion in the lung was 1 cm and in the liver was 1.5 cm. The serum half-life of In-111-labeled CCR 086 MoAb was approximately 64 hours. The formation of human antimouse antibody (HAMA) was detected in the serum of four of five patients who received 20 mg of MoAb. No HAMAs were detected in four patients receiving 5 mg of MoAb. No side effects were encountered. Because of effective detection of liver and lung metastases with lower doses (5-20 mg) of CCR 086 conjugated with In-111, further investigations are warranted to assess clinical and therapeutic potentials of CCR 086 in the management of colorectal cancer.
引用
收藏
页码:117 / 122
页数:6
相关论文
共 24 条
[1]  
ABDEL-NABI H, 1988, Journal of Nuclear Medicine, V29, P898
[2]  
ABDELHABI H, 1988, 2ND P C RAD RAD CANC, P80
[3]   IN-111 LABELED MONOCLONAL-ANTIBODY IMMUNOSCINTIGRAPHY IN COLORECTAL-CARCINOMA - SAFETY, SENSITIVITY, AND PRELIMINARY CLINICAL-RESULTS [J].
ABDELNABI, H ;
DOERR, RJ ;
CHAN, HW ;
BALU, D ;
SCHMELTER, RF ;
MAGUIRE, RT .
RADIOLOGY, 1990, 175 (01) :163-171
[4]   COLORECTAL TUMORS - SCINTIGRAPHY WITH IN-111 ANTI-CEA MONOCLONAL-ANTIBODY AND CORRELATION WITH SURGICAL, HISTOPATHOLOGIC, AND IMMUNOHISTOCHEMICAL FINDINGS [J].
ABDELNABI, HH ;
SCHWARTZ, AN ;
GOLDFOGEL, G ;
ORTMANNABI, JA ;
MATSUOKA, DM ;
UNGER, MW ;
WECHTER, DG .
RADIOLOGY, 1988, 166 (03) :747-752
[5]   COLORECTAL-CARCINOMA - DETECTION WITH IN-111 ANTICARCINOEMBRYONIC-ANTIGEN MONOCLONAL-ANTIBODY ZCE-025 [J].
ABDELNABI, HH ;
SCHWARTZ, AN ;
HIGANO, CS ;
WECHTER, DG ;
UNGER, MW .
RADIOLOGY, 1987, 164 (03) :617-621
[6]   TOMOSCINTIGRAPHY FOR DETECTING GASTROINTESTINAL AND MEDULLARY-THYROID CANCERS - 1ST CLINICAL-RESULTS USING RADIOLABELED MONOCLONAL-ANTIBODIES AGAINST CARCINOEMBRYONIC ANTIGEN [J].
BERCHE, C ;
MACH, JP ;
LUMBROSO, JD ;
LANGLAIS, C ;
AUBRY, F ;
BUCHEGGER, F ;
CARREL, S ;
ROUGIER, P ;
PARMENTIER, C ;
TUBIANA, M .
BRITISH MEDICAL JOURNAL, 1982, 285 (6353) :1447-1451
[7]   PERITONEAL CARCINOMATOSIS - IMAGING WITH INTRAPERITONEAL INJECTION OF I-131-LABELED B72.3 MONOCLONAL-ANTIBODY [J].
CARRASQUILLO, JA ;
SUGARBAKER, P ;
COLCHER, D ;
REYNOLDS, JC ;
ESTEBAN, J ;
BRYANT, G ;
PERENTESIS, P ;
YOKOYAMA, K ;
ROTMAN, M ;
SCHLOM, J ;
LARSON, SM .
RADIOLOGY, 1988, 167 (01) :35-40
[8]  
CARRASQUILLO JA, 1988, J NUCL MED, V29, P1022
[9]   DETECTION OF COLORECTAL-CARCINOMA BY EMISSION-COMPUTERIZED TOMOGRAPHY AFTER INJECTION OF I-123 LABELED FAB OR F(AB')2 FRAGMENTS FROM MONOCLONAL ANTICARCINOEMBRYONIC ANTIGEN ANTIBODIES [J].
DELALOYE, B ;
BISCHOFDELALOYE, A ;
BUCHEGGER, F ;
VONFLIEDNER, V ;
GROB, JP ;
VOLANT, JC ;
PETTAVEL, J ;
MACH, JP .
JOURNAL OF CLINICAL INVESTIGATION, 1986, 77 (01) :301-311
[10]   SCINTIGRAPHY WITH IN-111-LABELED MONOCLONAL ANTITUMOR ANTIBODIES - KINETICS, BIODISTRIBUTION, AND TUMOR-DETECTION [J].
HALPERN, SE ;
HAINDL, W ;
BEAUREGARD, J ;
HAGAN, P ;
CLUTTER, M ;
AMOX, D ;
MERCHANT, B ;
UNGER, M ;
MONGOVI, C ;
BARTHOLOMEW, R ;
JUE, R ;
CARLO, D ;
DILLMAN, R .
RADIOLOGY, 1988, 168 (02) :529-536