3-DIMENSIONAL RECONSTRUCTION OF HUMAN CAROTID ARTERIES FROM IMAGES OBTAINED DURING NONINVASIVE B-MODE ULTRASOUND EXAMINATION

被引:19
作者
ROSENFIELD, K
BOFFETTI, P
KAUFMAN, J
WEINSTEIN, R
RAZVI, S
ISNER, JM
机构
[1] ST ELIZABETH HOSP,DEPT MED,736 CAMBRIDGE ST,BOSTON,MA 02135
[2] ST ELIZABETH HOSP,DEPT SURG,BOSTON,MA 02135
[3] ST ELIZABETH HOSP,DEPT BIOMED RES,BOSTON,MA 02135
关键词
D O I
10.1016/0002-9149(92)90623-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Previous investigators have demonstrated that B-mode ultrasonography can provide high resolution images of the carotid arteries. When combined with Doppler flow measurements, quantitative estimates of luminal narrowing may also be obtained. B-mode imaging is limited, however, in its ability to provide a composite view of the vessel wall, lumen and plaque. Spatial relations between structures visualized in individual frames must be inferred from repeated transducer passes over the designated site, or repeated review of recorded images, followed by a "mind's eye" reconstruction. Three-dimensional (3-D) reconstruction of serially recorded cross-sectional images from current B-mode systems represents a possible solution to this limited spatial display that preserves detail regarding vessel wall pathology. Accordingly, computer-based automated 3-D reconstruction was used to generate a tangible format with which to assess and compare serially and transcutaneously recorded 2-dimensional (2-D) B-mode images of the carotid arteries. One or more timed sweep recordings of the 2-D B-mode examination were obtained from S patients for 3-D reconstruction. In all cases, satisfactory 3-D reconstruction was accomplished in three 3-D formats: cylindrical, sagittal and lumen cast. Sagittal 3-D reconstruction provided information regarding pathologic alterations within the arterial wall. Experience with the cylindrical mode suggests that this 3-D format, particularly when the reconstructed vascular segment is hemisected, is optimally suited for those cases in which direct inspection of luminal topography is of special interest. The lumen cast display, used with a recently validated edge-detection algorithm, may enhance the use of B-mode ultrasound for assessment of luminal cross-sectional area. This preliminary experience suggests that 3-D reconstruction may supplement in a meaningful way noninvasively recorded conventional B-mode images of the extracranial vasculature.
引用
收藏
页码:379 / 384
页数:6
相关论文
共 13 条
[1]   CAROTID SONOGRAPHY [J].
CARROLL, BA .
RADIOLOGY, 1991, 178 (02) :303-313
[2]   ANGIOGRAPHICALLY UNDETECTED ULCERATION OF THE CAROTID BIFURCATION ASA CAUSE OF EMBOLIC STROKE [J].
EDWARDS, JH ;
KRICHEFF, II ;
RILES, T ;
IMPARATO, A .
RADIOLOGY, 1979, 132 (02) :369-373
[3]   INACCURACY OF ANGIOGRAPHY IN THE DIAGNOSIS OF CAROTID ULCERATION [J].
EIKELBOOM, BC ;
RILES, TR ;
MINTZER, R ;
BAUMANN, FG ;
DEFILLIP, G ;
LIN, J ;
IMPARATO, AM .
STROKE, 1983, 14 (06) :882-885
[4]  
ISNER JM, 1992, TECHNOLGOIES VASCULA, P258
[5]  
ODONNELL TF, 1985, ARCH SURG-CHICAGO, V120, P443
[6]   CAROTID BIFURCATION DISEASE - PREDICTION OF ULCERATION WITH B-MODE US [J].
OLEARY, DH ;
HOLEN, J ;
RICOTTA, JJ ;
ROE, S ;
SCHENK, EA .
RADIOLOGY, 1987, 162 (02) :523-525
[7]   A PC-BASED 3D IMAGING-SYSTEM - ALGORITHMS, SOFTWARE, AND HARDWARE CONSIDERATIONS [J].
RAYA, SP ;
UDUPA, JK ;
BARRETT, WA .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1990, 14 (05) :353-370
[8]   LOW-LEVEL SEGMENTATION OF 3-D MAGNETIC-RESONANCE BRAIN IMAGES - A RULE-BASED SYSTEM [J].
RAYA, SP .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (03) :327-337
[9]  
RAYA SP, 1990, P SPIE MED IMAGING I, V1232, P152
[10]   3-DIMENSIONAL RECONSTRUCTION OF HUMAN CORONARY AND PERIPHERAL ARTERIES FROM IMAGES RECORDED DURING 2-DIMENSIONAL INTRAVASCULAR ULTRASOUND EXAMINATION [J].
ROSENFIELD, K ;
LOSORDO, DW ;
RAMASWAMY, K ;
PASTORE, JO ;
LANGEVIN, RE ;
RAZVI, S ;
KOSOWSKY, BD ;
ISNER, JM .
CIRCULATION, 1991, 84 (05) :1938-1956