QUANTIFICATION OF INTRAVENOUS CONTRAST-ENHANCED DOPPLER POWER SPECTRUM IN THE RABBIT CAROTID-ARTERY

被引:14
作者
FRUSH, DP
BABCOCK, DS
WHITE, KS
BARR, LL
机构
[1] UNIV CINCINNATI,COLL MED,CHILDRENS HOSP,MED CTR,DEPT RADIOL,CINCINNATI,OH
[2] UNIV CINCINNATI,COLL MED,CHILDRENS HOSP,MED CTR,DEPT PEDIAT,CINCINNATI,OH
[3] CHILDRENS HOSP & MED CTR,DEPT RADIOL,SEATTLE,WA 98105
关键词
DOPPLER SONOGRAPHY; SONOGRAPHIC CONTRAST AGENT; PERFLUBRON EMULSION; FLUOROCARBON; SONOGRAPHIC QUANTIFICATION; ANIMAL MODEL;
D O I
10.1016/0301-5629(94)00097-2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In vivo evaluation of Doppler contrast agent (DCA) enhancement has been principally qualitative. To quantitate the enhancement of the Doppler signal by perflubron emulsion, an investigational DCA, the audio-Doppler signal from the rabbit carotid artery was recorded during 0.5-ml/kg incremental doses to a total dose of 2.5 ml/kg. A representation of the recorded signal intensity, the Doppler power spectrum (DPS), was determined using a personal computer and commercially available software package. The dose related enhancement from perflubron emulsion was linear (r = 0.986, p = 0.0124) with a 710% (8.5 dB) overall enhancement at 2.5 ml/kg (p = 0.0001). Significant differences in enhancement could be detected with doses as low as 1.0 ml/kg and compared favorably with observer assessment of dose-related enhancement. This relatively simple method of computer analysis can quantify in vivo Doppler signal intensity and enhancement by perflubron emulsion and may enable quantitative comparisons between different DCAs.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 18 条
[1]   ENHANCEMENT OF THE ECHOGENICITY OF FLOWING BLOOD BY THE CONTRAST AGENT PERFLUBRON [J].
ANDRE, MP ;
STEINBACH, G ;
MATTREY, RF .
INVESTIGATIVE RADIOLOGY, 1993, 28 (06) :502-506
[2]  
BARNHART J, 1990, INVEST RADIOL, V25, P162
[3]   PERFLUOROOCTYLBROMIDE AS A CONTRAST AGENT FOR CT AND SONOGRAPHY - PRELIMINARY CLINICAL-RESULTS [J].
BEHAN, M ;
OCONNELL, D ;
MATTREY, RF ;
CARNEY, DN .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (02) :399-405
[4]  
BURNS PN, 1990, ANN INT C IEEE ENG M, V12, P322
[5]   POTENTIAL ROLE OF PFOB ENHANCED SONOGRAPHY OF THE KIDNEY .2. DETECTION OF PARTIAL INFARCTION [J].
COLEY, BD ;
MATTREY, RF ;
ROBERTS, A ;
KEANE, S .
KIDNEY INTERNATIONAL, 1991, 39 (04) :740-745
[6]  
COLEY BD, 1990, RADIOLOGY S, V177, P215
[7]  
HEIBERG E, 1990, RADIOLOGY S, V177, P177
[8]   IV-INJECTION OF AIR-FILLED HUMAN-ALBUMIN MICROSPHERES TO ENHANCE ARTERIAL DOPPLER SIGNAL - A PRELIMINARY-STUDY IN RABBITS [J].
HILPERT, PL ;
MATTREY, RF ;
MITTEN, RM ;
PETERSON, T .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (03) :613-616
[9]   PERFLUOROCTYLBROMIDE - A LIVER SPLEEN-SPECIFIC AND TUMOR-IMAGING ULTRASOUND CONTRAST MATERIAL [J].
MATTREY, RF ;
SCHEIBLE, FW ;
GOSINK, BB ;
LEOPOLD, GR ;
LONG, DM ;
HIGGINS, CB .
RADIOLOGY, 1982, 145 (03) :759-762
[10]   ULTRASOUND CONTRAST AGENTS - STATE-OF-THE-ART [J].
MATTREY, RF ;
STEINBACH, GC .
INVESTIGATIVE RADIOLOGY, 1991, 26 :S5-S11