CONVECTIVE-TRANSPORT IN DIFFUSIVE SAMPLERS

被引:6
作者
UNDERHILL, DW
机构
[1] School of Public Health, University of South Carolina, Columbia
关键词
D O I
10.1016/0039-9140(93)80031-L
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Convective transport in diffusive samplers was determined by the loss of a dilute dye solution from these samplers while held in a water bath. The water flow in the bath was adjusted to give the same Reynolds number had the diffusive sampler been exposed to an airborne analyte at a predetermined flow velocity. By numerical analysis, estimates were made of the degree of interference of convection on sampler performance. The results indicate an enormous difference between commercial diffusive samplers with respect to the effect of convection on the transport of analyte into the sampler.
引用
收藏
页码:785 / 790
页数:6
相关论文
共 15 条
[1]  
BROWN RH, 1989, AIR SAMPLING INSTRUM
[2]  
CASSINELLI ME, 1987, DIFFUSIVE SAMPLING A, P190
[3]  
Crank J., 1979, MATH DIFFUSION, V2nd
[4]  
Edwards W. M., 1984, PERRYS CHEM ENG HDB
[5]   BUOYANCY-DRIVEN EXCHANGE FLOW THROUGH SMALL OPENINGS IN HORIZONTAL PARTITIONS [J].
EPSTEIN, M .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1988, 110 (4A) :885-893
[6]  
HALLBERG BO, 1987, DIFFUSIVE SAMPLING A, P149
[7]  
MARPLE VA, 1970, U MINNESOTA PARTICLE, V144
[8]  
PALMERS ED, 1973, AM IND HYG, V32, P78
[9]  
PANNWITZ KH, 1987, DIFFUSIVE SAMPLING A, P157
[10]  
POZZOLI L, 1987, DIFFUSIVE SAMPLING A, P119