DETERMINATION OF TC-99 IN NUCLEAR SAMPLES BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY

被引:10
作者
ALONSO, JIG
SENA, F
KOCH, L
机构
[1] European Commission, JRC, Institute for Transuranium Elements, 76125 Karlsruhe
关键词
INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; TC-99; NUCLEAR WASTE;
D O I
10.1039/ja9940901217
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Different approaches for the determination of Tc-99 in various nuclear samples are described. Technetium has been determined in leachates of spent fuel and vitrified highly active waste using the elemental response curve of the instrument. It has been observed that Tc is preferentially leached-from spent fuel under oxidizing conditions (30% H2O2) indicating that the pertecnectate ion should be the leached species. It has also been determined in spent fuel dissolver solutions by the method of standard additions using other elements present in the sample as internal standards. Zirconium, Mo and Ru showed to be adequate internal standards for the determination of Tc in those samples. The formation of several polyatomic ions containing Tc was observed at high Tc concentrations. Peaks at m/z 115, 131 and 147 were assigned to TcO+, TcO2+ and TcO3+, the TcO2+ being the predominant polyatomic ion. The ratios of the polyatomic ion to the main Tc-99 peak were estimated with the help of Ph as internal standard. The influence of plasma operating conditions on the relative abundance of those polyatomic ions has been studied. It was also observed that Tc suffers from a long and persistent memory effect.
引用
收藏
页码:1217 / 1222
页数:6
相关论文
共 12 条
  • [1] ANALYTICAL-CHEMISTRY IN NUCLEAR TECHNOLOGY
    ACHE, HJ
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 343 (11): : 852 - 862
  • [2] DISSOLUTION STUDY OF SPENT PWR FUEL - DISSOLUTION BEHAVIOR AND CHEMICAL-PROPERTIES OF INSOLUBLE RESIDUES
    ADACHI, T
    OHNUKI, M
    YOSHIDA, N
    SONOBE, T
    KAWAMURA, W
    TAKEISHI, H
    GUNJI, K
    KIMURA, T
    SUZUKI, T
    NAKAHARA, Y
    MUROMURA, T
    KOBAYASHI, Y
    OKASHITA, H
    YAMAMOTO, T
    [J]. JOURNAL OF NUCLEAR MATERIALS, 1990, 174 (01) : 60 - 71
  • [3] PERFORMANCE-CHARACTERISTICS OF A GLOVE BOX INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETER FOR THE ANALYSIS OF NUCLEAR-MATERIALS
    ALONSO, JIG
    THOBYSCHULTZENDORFF, D
    GIOVANONNE, B
    KOCH, L
    WIESMANN, H
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (05) : 673 - 679
  • [4] ALONSO JIG, 1993, RADIOCHIM ACTA, V62, P71
  • [5] ALONSO JIG, 1994, J ANAL AT SPECTROM, V9
  • [6] THE MEASUREMENT OF LONG LIVED RADIONUCLIDES BY NON-RADIOMETRIC METHODS
    BROWN, RM
    LONG, SE
    PICKFORD, CJ
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 1988, 70 : 265 - 274
  • [7] INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY OF SYNTHETIC ELEMENTS - TC-99
    CRAIN, JS
    GALLIMORE, DL
    [J]. APPLIED SPECTROSCOPY, 1992, 46 (03) : 547 - 549
  • [8] GLATZ JP, 1992, 3RD INT C NUCL RAD V
  • [9] GLATZ JP, IN PRESS J NUCL MAT
  • [10] KIM C-K, 1989, Radioisotopes, V38, P151