DETECTION OF GALACTOSE AND LACTOSE BY A POLY(AMPHIPHILIC PYRROLE)-GALACTOSE OXIDASE ELECTRODE

被引:36
作者
COSNIER, S
INNOCENT, C
机构
[1] Laboratoire d'Electrochimie Organique et de Photochimie Rédox, URA Cnrs 1210, Université Joseph Fourier Grenoble 1, 38041, Grenoble Cedex 9
关键词
ENZYME SENSOR; POLY(AMPHIPHILIC PYRROLE); OVERLYING POLYMER; AMPEROMETRIC DETECTION; GALACTOSE; LACTOSE;
D O I
10.1080/00032719408006380
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The entrapment of galactose oxidase (GAO) on an electrode surface by coadsorption with a cationic amphiphilic pyrrole and electropolymerization of this pyrrole monomer is described. This simple and rapid procedure for biosensor construction provides very fast responsive and sensitive GAO-based sensors to galactose and lactose. The electrode response is based on the electrochemical detection of enzymically generated hydrogen peroxide. The stability, optimum pH and selectivity of the bioelectrode as well as the characteristics of the immobilized galactose oxidase have been determined. Poly(amphiphilic pyrrole) films have been electrogenerated on the surface of the bioelectrode and the effect of such additional coatings on the biosensor selectivity have also been examined.
引用
收藏
页码:1429 / 1442
页数:14
相关论文
共 27 条
[1]  
AVIGAD G, 1962, J BIOL CHEM, V237, P2736
[2]   ELECTROCHEMISTRY OF THE POLYPYRROLE GLUCOSE-OXIDASE ELECTRODE [J].
BELANGER, D ;
NADREAU, J ;
FORTIER, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 274 (1-2) :143-155
[3]   MULTIPURPOSE ELECTRODE WITH DIFFERENT ENZYME-SYSTEMS BOUND TO COLLAGEN FILMS [J].
BERTRAND, C ;
COULET, PR ;
GAUTHERON, DC .
ANALYTICA CHIMICA ACTA, 1981, 126 (MAY) :23-34
[4]   AMPEROMETRIC SENSOR AND IMMOBILIZED ENZYME ELECTRODE FOR THE DETERMINATION OF ENZYMATIC-ACTIVITIES [J].
BLUM, LJ ;
BERTRAND, C ;
COULET, PR .
ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1983, 16 (07) :525-540
[5]   APPLICATIONS OF IMMOBILIZED BIOCATALYSTS IN CHEMICAL-ANALYSIS [J].
BOWERS, LD .
ANALYTICAL CHEMISTRY, 1986, 58 (04) :A513-&
[6]   RAPID ASSAY OF GALACTOSE IN BLOOD-SERUM AND URINE BY AMPEROMETRIC MEASUREMENT OF ENZYME-CATALYZED OXYGEN-CONSUMPTION [J].
CHENG, FS ;
CHRISTIAN, GD .
ANALYTICA CHIMICA ACTA, 1979, 104 (01) :47-53
[7]   IMMOBILIZATION OF REDOX ANIONS IN POLY(AMPHIPHILIC PYRROLYLALKYLAMMONIUM) USING A SIMPLE AND MONOMER-SAVING ONE-STEP PROCEDURE IN PURE WATER-ELECTROLYTE [J].
COCHEGUERENTE, L ;
DERONZIER, A ;
GALLAND, B ;
LABBE, P ;
MOUTET, JC ;
REVERDY, G .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1991, (06) :386-388
[8]  
COCHEGUERENTE L, IN PRESS ELECTROANAL
[9]   OXIDATIVE ELECTROPOLYMERIZATION OF POLYPYRIDINYL COMPLEXES OF RUTHENIUM(II)-CONTAINING PYRROLE GROUPS [J].
COSNIER, S ;
DERONZIER, A ;
MOUTET, JC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 193 (1-2) :193-204
[10]   CONTROLLED PERMEABILITY OF FUNCTIONALIZED POLYPYRROLE FILMS BY USE OF DIFFERENT ELECTROLYTE ANION SIZES IN THE ELECTROPOLYMERIZATION STEP [J].
COSNIER, S ;
DERONZIER, A ;
ROLAND, JF .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 310 (1-2) :71-87