WATER TEMPERATURE AND ACCURACY OF ALGINATE IMPRESSIONS

被引:14
作者
HARRIS, WT
机构
[1] Temple University, School of Dentistry, Philadelphia, PA
关键词
D O I
10.1016/0022-3913(69)90008-0
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
This investigation was undertaken to determine the influence of the temperature of the water used for mixing on the accuracy of alginate impressions. A total of thirty gypsum casts were made with three brands of impression material and four water temperatures. Six dimensions were evaluated. No significant differences due to water temperature were observed. Dimensional changes that appear to be related to other factors were observed in all casts. © 1969 The C. V. Mosby Company.