THE SICK BUILDING SYNDROME .1. DEFINITION AND EPIDEMIOLOGIC CONSIDERATIONS

被引:22
作者
CHANG, CC [1 ]
RUHL, RA [1 ]
HALPERN, GM [1 ]
GERSHWIN, ME [1 ]
机构
[1] UNIV CALIF DAVIS,SCH MED,DEPT INTERNAL MED,DIV RHEUMATOL ALLERGY & CLIN IMMUNOL,TB 192,DAVIS,CA 95616
关键词
D O I
10.3109/02770909309054529
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
It has been difficult to confirm that a given building is responsible for allergic symptomatology, exacerbation of asthma, or immunological dysfunction. In fact, in most studies, few objective immunological parameters have been studied and only rarely has there been any quantitation of IgE or secondary mediators. Furthermore, although many studies deal with rhinitis or respiratory tract irritation, there is a misconception that all such symptoms are allergic in nature, and studies attempting to prove that allergies are caused by buildings frequently neglect to prove that these are indeed true allergic responses. In addition, many of the symptoms that people attribute to sick building syndrome (SBS) or building-related illness, such as headaches, dizziness, fatigue, nausea, cough, and eye irritation, are subjective, and studies often fail to take into account other possible causes that may be inherent in the subjects, such as sinusitis, hyperventilation syndrome, or psychosomatic illness. Unfortunately, most clinical studies on SBS pay little attention to the preexisting conditions that a subject may have and discount the possibility that the inciting agent does not cause symptoms, but merely exacerbates a preexisting condition. Moreover, they offer no information about the nature of the mechanisms of action or pathophysiological relationships. Clearly, further studies are necessary to further explain the complexity of complaints that currently exist. Indeed, SBS might properly be paraphrased as ''What is it?-if it is!''
引用
收藏
页码:285 / 295
页数:11
相关论文
共 51 条
[1]  
Bardana E.J., Montanaro A., O'Hollaren M.T., Building-related illness. A review of available scientific data, Clin Rev Allergy, 6, (1988)
[2]  
Lyles W.B., Greve K.W., Bauer R.M., Ware M.R., Schramke C.J., Crouch J., Hicks A., Sick building syndrome, Southern Med J, 84, (1991)
[3]  
Brandt-Rauf P.W., Andres L.R., Schwarz-Miller J., Sick-hospital syndrome, J Occup Med, 33, (1991)
[4]  
Glick T.H., Gregg M.B., Berman B., Mallison G., Rhodes W.N., Kassanoff I., Pontiac fever: An epidemic of unknown etiology in a health department. I. Clinical and epidemiological aspects, Am J Epidemiol, 107, (1987)
[5]  
Finnegan M.J., Pickering C.A.C., Burge P.S., The sick building syndrome: Prevalence studies, Br Med J, 289, (1984)
[6]  
Kreiss K., State of the art review: The epidemiology of building-related complaints and illness, Occup Med, 4, (1989)
[7]  
Norback D., Torgen M., Elding C., Volatile organic compounds, respirable dust, and personal factors related to prevalence and incidence of sick building syndrome in primary schools, Br J Indust Med, 47, (1990)
[8]  
Burge S., Hedge A., Wilson S., Bass J.H., Robertson A., Sick building syndrome: A study of 4373 office workers, Ann Occup Hyg, 31, (1987)
[9]  
Robertson A.S., Burge S., Hedge A., Sims J., Gill F.S., Finnegan M., Pickering C.A.C., Dalton G., Comparison of health problems related to work and environmental measurements in two office buildings with different ventilation systems, Br Med J, 291, (1985)
[10]  
Sterling T.D., Kobayashi D., Exposure to pollutants in enclosed “living spaces”, Environ Res, 13, (1977)