PERITONEAL OVARIAN METASTASES SIMULATING LIVER PARENCHYMAL METASTASES

被引:8
作者
LUNDSTEDT, C [1 ]
HOLMIN, T [1 ]
THORVINGER, B [1 ]
机构
[1] UNIV LUND HOSP,DEPT SURG,S-22185 LUND,SWEDEN
来源
GASTROINTESTINAL RADIOLOGY | 1992年 / 17卷 / 03期
关键词
OVARIAN NEOPLASMS; CT; LIVER METASTASES;
D O I
10.1007/BF01888560
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Ovarian carcinoma frequently metastasizes to the peritoneum, both locally in the pelvis and elsewhere. Computed tomography (CT) has a limited ability to identify peritoneal implants with a diameter of 2 cm or less. Three cases of subphrenic, diaphragmatic peritoneal implants, preoperatively at CT thought to represent liver parenchymal metastases, are presented. The difficulty in the differentiation of diaphragmatic peritoneal implants from metastases to the capsule and parenchyma of the liver is discussed. To achieve a radical liver resection in patients with ovarian carcinoma, metastatic peritoneal implants must be excluded during operation.
引用
收藏
页码:250 / 252
页数:3
相关论文
共 10 条
[1]  
BRENNER DE, 1985, OBSTET GYNECOL, V65, P715
[2]   PERITONEAL IMPLANTS FROM OVARIAN-TUMORS - CT FINDINGS [J].
BUY, JN ;
MOSS, AA ;
GHOSSAIN, MA ;
SCIOT, C ;
MALBEC, L ;
VADROT, D ;
PANIEL, BJ ;
DECROIX, Y .
RADIOLOGY, 1988, 169 (03) :691-694
[3]   COMPUTED-TOMOGRAPHY IN EVALUATION OF PATIENTS WITH OVARIAN-CARCINOMA IN COMPLETE CLINICAL REMISSION - CORRELATION WITH SURGICAL-PATHOLOGICAL FINDINGS [J].
CLARKEPEARSON, DL ;
BANDY, LC ;
DUDZINSKI, M ;
HEASTON, D ;
CREASMAN, WT .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1986, 255 (05) :627-630
[4]   LIVER-TUMOR IMAGING - CURRENT CONCEPTS [J].
FERRUCCI, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (03) :473-484
[5]   THE ACCURACY OF COMPUTED-TOMOGRAPHY OF THE LIVER IN COLORECTAL-CARCINOMA [J].
LUNDSTEDT, C ;
EKBERG, H ;
HEDERSTROM, E ;
TRANBERG, KG .
CLINICAL RADIOLOGY, 1990, 42 (05) :335-339
[6]   ACCURACY OF CT IN DETECTION OF PERSISTENT OR RECURRENT OVARIAN-CARCINOMA - CORRELATION WITH 2ND-LOOK LAPAROTOMY [J].
MEGIBOW, AJ ;
BOSNIAK, MA ;
HO, AG ;
BELLER, U ;
HULNICK, DH ;
BECKMAN, EM .
RADIOLOGY, 1988, 166 (02) :341-345
[7]   DISTRIBUTION OF INTRAABDOMINAL MALIGNANT SEEDING - DEPENDENCY ON DYNAMICS OF FLOW OF ASCITIC FLUID [J].
MEYERS, MA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1973, 119 (01) :198-206
[8]  
THORVINGER B, 1987, ACTA RADIOL, V28, P739
[9]   USE OF THE COMPUTED TOMOGRAPHIC WHOLE-BODY SCANNER TO STAGE AND FOLLOW PATIENTS WITH ADVANCED OVARIAN-CARCINOMA [J].
WHITLEY, N ;
BRENNER, D ;
FRANCIS, A ;
KWON, T ;
VILLASANTA, U ;
AISNER, J ;
WIERNIK, P ;
WHITLEY, J .
INVESTIGATIVE RADIOLOGY, 1981, 16 (06) :479-486
[10]  
1984, SWEDISH NATIONAL CAN