DETERMINANTS OF RELEASE RATE OF TETANUS VACCINE FROM POLYESTER MICROSPHERES

被引:211
作者
ALONSO, MJ
COHEN, S
PARK, TG
GUPTA, RK
SIBER, GR
LANGER, R
机构
[1] MIT,DEPT CHEM ENGN,CAMBRIDGE,MA 02139
[2] MASSACHUSETTS PUBL HLTH BIOL LABS,BOSTON,MA 02130
关键词
VACCINE DELIVERY SYSTEM; CONTROLLED RELEASE; POLY(LACTIC GLYCOLIC ACID); BIODEGRADABLE MICROSPHERES; TETANUS;
D O I
10.1023/A:1018942118148
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Controlled-release formulations based on poly(lactic) (PLA) and poly(lactic/glycolic) acid (PLGA) microspheres containing tetanus vaccine were designed. The polymers forming the microspheres were L-PLA of different molecular weights and DL-PLGA, 50:50. These microspheres were prepared by two solvent elimination procedures, both using a double emulsion, and were characterized for size, morphology, and toxoid release kinetics. The influence of formulation variables such as polymer type, vaccine composition, and vaccine/polymer ratio was also investigated. Both techniques yielded microspheres with similar size, morphology, and release properties. Microsphere size was dependent on the type of polymer and the presence of the surfactant L-alpha-phosphatidylcholine, which led to a reduction in microsphere size. On the other hand, the release kinetics of encapsulated protein were affected by the polymer properties (ratio lactic/glycolic acid and molecular weight) as well as by the vaccine composition, vaccine loading, and microsphere size. Moreover, for some formulations, a decrease in microsphere size occurred simultaneously, with an increase in porosity leading to an augmentation of release rate. The changes in the PLA molecular weight during in vitro release studies indicated that release profiles of tetanus toxoid from these microspheres were only marginally influenced by polymer degradation. A significant fraction of protein (between 15 and 35%) was initially released by diffusion through water-filled channels. In contrast, the decrease in the PLGA molecular weight over the first 10 days of incubation suggested that erosion of the polymer matrix substantially affects protein release from these microspheres. Among all formulations developed, two differing in microsphere size, polymer hydrophobicity, and release profile were selected for in vivo administration to mice. Administration of both formulations resulted in tetanus neutralizing antibody levels that were higher than those obtained after administration of the fluid toxoid.
引用
收藏
页码:945 / 953
页数:9
相关论文
共 21 条
  • [1] ALONSO MJ, UNPUB VACCINE
  • [2] BOHN L, 1975, POLYM HDB, P211
  • [3] CONTROLLED DELIVERY SYSTEMS FOR PROTEINS BASED ON POLY(LACTIC GLYCOLIC ACID) MICROSPHERES
    COHEN, S
    YOSHIOKA, T
    LUCARELLI, M
    HWANG, LH
    LANGER, R
    [J]. PHARMACEUTICAL RESEARCH, 1991, 8 (06) : 713 - 720
  • [4] BIODEGRADABLE AND BIOCOMPATIBLE POLY(DL-LACTIDE-CO-GLYCOLIDE) MICROSPHERES AS AN ADJUVANT FOR STAPHYLOCOCCAL ENTEROTOXIN-B TOXOID WHICH ENHANCES THE LEVEL OF TOXIN-NEUTRALIZING ANTIBODIES
    ELDRIDGE, JH
    STAAS, JK
    MEULBROEK, JA
    TICE, TR
    GILLEY, RM
    [J]. INFECTION AND IMMUNITY, 1991, 59 (09) : 2978 - 2986
  • [5] EPPSTEIN DA, 1988, CRC CR REV THER DRUG, V5, P99
  • [6] PARAMETERS AFFECTING THE IMMUNOGENICITY OF MICROENCAPSULATED TETANUS TOXOID
    ESPARZA, I
    KISSEL, T
    [J]. VACCINE, 1992, 10 (10) : 714 - 720
  • [7] GALAZKA A, 1989, 8TH P INT C TET, P470
  • [8] THE TITRATION OF TETANUS ANTITOXIN .4. STUDIES ON THE SENSITIVITY AND REPRODUCIBILITY OF THE TOXIN NEUTRALIZATION TEST
    GUPTA, RK
    MAHESHWARI, SC
    SINGH, H
    [J]. JOURNAL OF BIOLOGICAL STANDARDIZATION, 1985, 13 (02): : 143 - 149
  • [9] RELEASE OF HUMAN SERUM-ALBUMIN FROM POLY(LACTIDE-CO-GLYCOLIDE) MICROSPHERES
    HORA, MS
    RANA, RK
    NUNBERG, JH
    TICE, TR
    GILLEY, RM
    HUDSON, ME
    [J]. PHARMACEUTICAL RESEARCH, 1990, 7 (11) : 1190 - 1194
  • [10] BIODEGRADABLE POLYMER SYSTEMS FOR THE SUSTAINED-RELEASE OF POLYPEPTIDES
    HUTCHINSON, FG
    FURR, BJA
    [J]. JOURNAL OF CONTROLLED RELEASE, 1990, 13 (2-3) : 279 - 294